Schneider TeSys K LP2K1210LD Reversing Contactor, 3P, 12A AC

MPNLP2K1210LD
Active

Schneider TeSys K reversing contactor, 3P, AC-3 ≤440 V 12 A, 1 NO, 200 V DC coil, preassembled with reversing power busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LP2K1210LD — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationResistive load Motor control
LP2K1210LD — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-4 AC-1
LP2K1210LD — Contacts & Poles
ParameterValue
Pole configuration3P
LP2K1210LD — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP2K1210LD — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The Schneider TeSys K LP2K1210LD is a 3-pole reversing contactor rated for AC-3 duty at 12 A up to 440 V, with a 200 V DC coil and one normally open auxiliary contact. It comes preassembled with the reversing power busbar — that means it's ready to drop into a panel for forward/reverse motor control without sourcing a separate mechanical interlock or bus kit. The 200 V DC coil is a specific voltage; verify your control supply matches before wiring.

The AC-3 rating of 12 A at 440 V governs motor switching — that's the current it can make and break across typical induction motor loads. AC-4 (inching/plugging) and AC-1 (resistive) are also listed, so the contactor can handle mixed duty cycles. The power circuit is rated up to 690 V AC 50/60 Hz, giving headroom for 480 V or 575 V systems as long as the motor current stays within the 12 A AC-3 limit.

Mechanical and environmental tolerance

The contactor handles 15 Gn shock on Z axis when closed, and 4 Gn vibration from 5 to 300 Hz — figures that matter if this goes into a machine with frequent start/stop jolts or a mobile application. Operating altitude is 2000 m without derating; above that you'll need to account for reduced air density on arc extinction.

Frequently asked questions

What are the key ratings for this reversing contactor?

AC-3 motor switching rated 12 A at ≤440 V, with a 200 V DC coil. The power circuit withstands up to 690 V AC. It has 3 NO main poles and 1 NO auxiliary contact.

What is the closest alternative if I cannot source this exact part?

Within the TeSys K family, a reversing contactor with a different coil voltage (e.g., 24 V DC or 110 V AC) would be the parametric alternative, but the 200 V DC coil is specific. No direct pin-compatible replacement outside this series is documented.

What compliance documentation is available for this part?

The contactor carries IP20 protection per VDE 0106 and flame retardance V1 per UL 94. It meets IEC 60068 for environmental robustness. RoHS and REACH compliance is standard for Schneider current-production parts, though specific certificates should be confirmed at order.