Schneider Electric LP2K1210LD3 — Contactors

TeSys K LP2K1210LD3 reversing contactor, 3P, AC-3 12 A, 200

MPNLP2K1210LD3
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 12 A, 1 NO, 200 V DC coil.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LP2K1210LD3 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationResistive load Motor control
LP2K1210LD3 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-1 AC-4
LP2K1210LD3 — Contacts & Poles
ParameterValue
Pole configuration3P
LP2K1210LD3 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP2K1210LD3 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The LP2K1210LD3 is a TeSys K reversing contactor from Schneider Electric, a 3-pole unit rated AC-3 at 12 A up to 440 V with a 200 V DC coil and one normally open auxiliary contact.

The 200 V DC coil means the control voltage is DC, not AC — verify your control transformer or power supply delivers 200 V DC nominal; the coil will hold in at that voltage and drop out reliably below the pick-up threshold.

This reversing contactor is built for a control panel — it snaps onto a DIN rail (IP20 finger-safe protection per VDE 0106) and measures 90 mm wide by 58 mm tall by 57 mm deep, so it fits a standard 90 mm-wide enclosure footprint. The preassembled reversing busbar saves an hour of wiring on a forward/reverse starter.

Frequently asked questions

What is the depth of LP2K1210LD3?

The depth is 57 mm.

What range does LP2K1210LD3 belong to?

It belongs to the TeSys range, specifically the TeSys K series.

What compliance documentation is available for LP2K1210LD3?

The part carries a V1 flame-retardance rating per UL 94, and meets NF F 16-101 and NF F 16-102 requirements. Protective treatment conforms to IEC 60068 and DIN 50016. The IP20 protection degree is per VDE 0106.

MPN