It's a 3-pole device with three normally-open power poles and one normally-open auxiliary contact, intended for control applications on resistive or motor loads. The utilisation categories cover AC-1 (resistive), AC-3 (squirrel-cage motor starting), and AC-4 (plugging/inching). At AC-3 duty up to 440 V, it's rated for 12 A — that's the figure that governs motor-switching fit for a typical 5.5 kW motor at 400 V. The coil is 60 V DC, so verify your control voltage matches; the contactor itself carries IP20 protection per VDE 0106 — finger-safe but not washdown-rated.
Schneider TeSys K LP2K1210ND Reversing Contactor, 3P, 12 A A
MPNLP2K1210ND
Active
Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NO, 60 V DC coil.
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026
Specifications
| Parameter | Value |
|---|---|
| Product / component type | Reversing contactor |
| Series / range | TeSys |
| Application | Resistive load Motor control |
| Parameter | Value |
|---|---|
| Rated operational voltage (Ue) | Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit |
| Utilisation category | AC-1 AC-4 AC-3 |
| Parameter | Value |
|---|---|
| Pole configuration | 3P |
| Parameter | Value |
|---|---|
| IP degree of protection | IP20 conforming to VDE 0106 |
| Operating altitude | 2000 m without derating |
| Mechanical robustness | Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 |
| Protective treatment / pollution degree | TC conforming to IEC 60068 TC conforming to DIN 50016 |
| Flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
| Parameter | Value |
|---|---|
| Width | 90 mm |
| Height | 58 mm |
| Depth | 57 mm |
Product details
Frequently asked questions
What are the key ratings I need to check for fit?
AC-3 motor-switching current is 12 A at 440 V, coil is 60 V DC, and the power circuit is rated for 690 V AC. The contactor has 3 NO power poles and 1 NO auxiliary contact.
What compliance documentation is available for this part?
The contactor carries V1 flame retardance per UL 94, IP20 per VDE 0106, and shock/vibration qualification per IEC 60068-2-27 and -2-6. It also meets NF F 16-101/102 for railway fire-smoke-toxicity.
MPN
LP2K1210ND