Skip to main content
Schneider Electric LP2K1210MD3 — Contactors

Schneider TeSys K LP2K1210MD3 Reversing Contactor, 3P, AC-3

MPNLP2K1210MD3
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 12 A at 440 V, 1 NO auxiliary contact, 220 V DC coil, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LP2K1210MD3 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationResistive load Motor control
LP2K1210MD3 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-1 AC-4
LP2K1210MD3 — Contacts & Poles
ParameterValue
Pole configuration3P
LP2K1210MD3 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP2K1210MD3 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The LP2K1210MD3 is a TeSys K reversing contactor from Schneider Electric — a 3-pole unit preassembled with a reversing power busbar, rated for AC-3 motor duty at 12 A up to 440 V and AC-1 resistive loads. The coil pulls in on 220 V DC. A single NO auxiliary contact is built in. IP20 finger-safe terminals suit it for enclosed panel mounting.

This order code is marked obsolete by the manufacturer. There is no official successor listed. The buyer should confirm the 220 V DC coil voltage and AC-3 current rating match the application before committing.

The AC-3 rating of 12 A at 440 V governs motor switching — that's the current the contactor can make and break across inductive motor loads. AC-1 resistive rating will be higher, but the motor duty number is the one that decides fit for a reversing starter. The 220 V DC coil means the control circuit must supply that voltage; a 24 V DC coil version would be a different order code.

Mechanical and environmental robustness

Rated for 15 Gn shock when closed and 10 Gn when open (Z axis), with vibration resistance of 4 Gn closed and 2 Gn open across 5–300 Hz per IEC 60068-2-6 and -2-27. Flame retardance meets V1 per UL 94 and NF F 16-101/102. Protective treatment conforms to IEC 60068 and DIN 50016 for humidity and corrosion resistance.

Frequently asked questions

What are the key ratings for the LP2K1210MD3?

It is a 3-pole reversing contactor rated for AC-3 motor duty at 12 A up to 440 V, with a 220 V DC coil and one NO auxiliary contact.

How do I source this obsolete part?

The LP2K1210MD3 is sourced through surplus and broker channels. Submit an RFQ for a quote; availability and pricing vary by lot.

What is the IP rating and operating temperature range?

IP20 per VDE 0106. Operating ambient temperature is -25°C to 50°C.

MPN
LP2K1210MD3