Schneider Electric VW3A5102 — AC Drive (VFD) 600V

Schneider Electric VW3A5102 Motor Choke, 48 A

MPNVW3A5102
Obsolete

Schneider Electric VW3A5102 motor choke, Altivar series, 48 A rated current, dv/dt 500 V/µs at 400 V / 750 V/µs at 500 V / 1000 V/µs at 690 V, 250 W thermal losses, IP20 with kits.

$220.98Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

VW3A5102 — Identification
ParameterValue
Product / component typeMotor choke

Mechanical

VW3A5102 — Mechanical
ParameterValue
Terminal / wiring connectionTerminal, connection capacity: 10 mm² / AWG 6

Environmental

VW3A5102 — Environmental
ParameterValue
IP rating (with kit options)IP20 (with kits VW3A9612,613) IP00
Operating ambient temperature-10...50 °C
Storage temperature-25...70 °C

Other specifications

VW3A5102 — Other specifications
ParameterValue
Dv (Dt)500 V/µs max at 400 V 750 V/µs max at 500 V 1000 V/µs max at 690 V
Thermal losses250 W
Nedded quantity1
Protection typeThermal protection by temperature-controlled switch, tripping temperature: 125 °C for <250 V AC, <0.5 A
Tightening torque1.5 N.m
Current48 A
Maximum motor cable length200 m shielded cable P motor 2.2...7.5 kW at 200...240 V 1 260 m unshielded cable P motor 2.2...7.5 kW at 200...240 V 1 85 m shielded cable P motor 0.75...18.5 kW at 380...480 V 1 95 m unshielded cable P motor 0.75...18.5 kW at 380...480 V 1 50 m shielded cable P motor 2.2...7.5 kW at 500...600 V 1 100 m unshielded cable P motor 2.2...7.5 kW at 500...600 V 1 45 m shielded cable P motor 2.2...11 kW at 500...690 V 1 70 m unshielded cable P motor 2.2...11 kW at 500...690 V 1
Product specific applicationOutput filter
Maximum drive output frequency100 Hz

Product details

dv/dt suppression that protects motor windings

The VW3A5102 is a motor choke — an output filter that sits between the drive and the motor to limit the voltage rise rate (dv/dt) that stresses winding insulation. At 400 V it holds dv/dt to 500 V/µs max; at 690 V the limit rises to 1000 V/µs max. That range covers the common 400 V and 690 V industrial supply rails, so the same choke works across a 380–690 V drive output without swapping parts. Rated 48 A continuous, it matches drives in the 22–37 kW range at 400 V. The 250 W thermal loss is the heat it dumps into the cabinet — budget that into the panel ventilation calculation so the choke doesn't raise the internal ambient above its -10…50 °C operating limit.

Cable length limits per voltage class

Maximum motor cable length depends on voltage and whether the cable is shielded. At 380–480 V, shielded cable runs up to 85 m; unshielded goes to 95 m. At 500–690 V, shielded drops to 45 m, unshielded to 70 m. These limits are the choke's design envelope — exceeding them risks reflected-wave overvoltage at the motor terminals. The choke also includes a thermal protection switch that trips at 125 °C (for <250 V AC, <0.5 A). That's a hard cut-off if the choke overheats from overload or poor ventilation — it doesn't reset automatically, so plan for a manual reset in the fault-handling sequence.

Obsolete — sourced through independent channels

Schneider has marked the VW3A5102 as obsolete. No official successor is listed. For a line-down spare or a BOM fill, the part is available through independent surplus and broker channels — quantities are lot-specific and confirmed at RFQ. No pin-compatible direct replacement exists from the original manufacturer; a functional alternative would need a different order code and possibly a mounting adapter. Terminal connection accepts up to 10 mm² / AWG 6, tightening torque 1.5 N·m. The IP20 rating (with the VW3A9612/613 kits) or IP00 without means it's intended for enclosure mounting — not a standalone outdoor install.

Frequently asked questions

What is the dv/dt rating of VW3A5102?

500 V/µs max at 400 V, 750 V/µs max at 500 V, and 1000 V/µs max at 690 V. These limits protect motor winding insulation from reflected-wave stress on long cable runs.

What are the thermal losses of VW3A5102?

250 W. This heat must be removed from the enclosure to keep the ambient within the -10…50 °C operating range.

MPN
VW3A5102