Skip to main content
SICK OD2-N120W60A2 — Proximity Sensors

OD2-N120W60A2 2D Laser Displacement Sensor, 120mm Range, NPN

MPNOD2-N120W60A2
Active

OD Value series 2D Laser Displacement Sensor, OD2-N120W60A2, 12~24VDC, NPN output, 120mm ±60mm sensing range, IP67, chassis mount, cable leads.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

OD2-N120W60A2 — Identification
ParameterValue
SeriesOD Value
Type2D Laser Displacement Sensor
OD2-N120W60A2 — Mechanical
ParameterValue
Mounting typeChassis Mount
OD2-N120W60A2 — Environmental
ParameterValue
Operating temperature range-10°C~40°C
OD2-N120W60A2 — Other specifications
ParameterValue
Supply voltage12 ~ 24VDC
Termination styleCable Leads
IP ratingIP67 - Dust Tight, Waterproof
Installation distance60.0mm ~ 180.0mm

Product details

Sensor type and what it measures

The OD2-N120W60A2 is a 2D Laser Displacement Sensor from the OD Value series, meaning it projects a laser line and measures profile displacement across a 120mm span with ±60mm range relative to the reference distance. The NPN output (open collector) switches low when the target is within the programmed window — standard for legacy PLC inputs that sink current. Supply is 12~24VDC, so it runs off a common industrial power rail without a separate converter.

Chassis-mount form factor with cable leads — no connector to mate, just gland the cable into the panel or junction box. Installation distance is adjustable from 60.0mm to 180.0mm, so you set the standoff to match the target height variation; the 120mm measurement width scales with that distance.

Temperature limits and derating

Rated for -10°C to 40°C operating ambient. That 40°C ceiling is the limiting factor for enclosure placement — if the sensor is inside a sealed cabinet near a heat source (drive, power supply), verify internal temperature stays under that. No derating curve is published in the basic spec, so keep the ambient below the limit to avoid measurement drift.

Frequently asked questions

What is the sensing range and output type of OD2-N120W60A2?

It has a 120mm measurement span with ±60mm range relative to the reference distance, and provides an NPN open-collector output.

Will OD2-N120W60A2 drop into a panel specified around OD2-N120W60U2 without rewiring?

Yes — the two share identical mechanical footprint, mounting, supply voltage, cable termination, IP rating, and installation distance. The only difference is the output type: the A2 variant is NPN, while the U2 is PNP. If the PLC input card expects a sinking (NPN) signal, the A2 is a direct swap; if the card expects sourcing (PNP), you need the U2.

How do I get current pricing and availability for OD2-N120W60A2?

Submit an RFQ through this listing. The part is sourced to order via independent distribution; current pricing and stock position are confirmed at quote time.

What compliance documentation does this brand provide for OD2-N120W60A2?

The evidence does not list specific compliance documents (RoHS, REACH, UL, IEC) for this order code. Request the manufacturer's declaration of conformity or certificate with your RFQ if your quality system requires it.

MPN
OD2-N120W60A2