Skip to main content
SICK OD2-N120W60I2 — Proximity Sensors

OD2-N120W60I2 2D Laser Displacement Sensor, 120mm ±60mm NPN

MPNOD2-N120W60I2
Active

Manufacturer: OD Value, Type: 2D Laser Displacement Sensor, Order Code: OD2-N120W60I2, Supply: 12~24VDC, Output: NPN, Range: 120mm ±60mm, IP67.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

OD2-N120W60I2 — Identification
ParameterValue
SeriesOD Value
Type2D Laser Displacement Sensor
OD2-N120W60I2 — Mechanical
ParameterValue
Mounting typeChassis Mount
OD2-N120W60I2 — Environmental
ParameterValue
Operating temperature range-10°C~40°C
OD2-N120W60I2 — Other specifications
ParameterValue
Supply voltage12 ~ 24VDC
Termination styleCable Leads
IP ratingIP67 - Dust Tight, Waterproof
Installation distance60.0mm ~ 180.0mm

Product details

The OD2-N120W60I2 is a 2D laser displacement sensor from the OD Value series, delivering a 120mm measurement range with ±60mm offset from the reference distance. It runs on 12~24VDC and provides an NPN discrete output — the I2 suffix indicates the NPN output variant. The sensor is chassis-mount with cable leads, rated IP67 for dust-tight and waterproof operation in washdown or outdoor environments.

Installation and deployment context

Installation distance spans 60.0mm to 180.0mm, giving flexibility for varying target heights on a conveyor or assembly line. The IP67 rating means the sensor body and cable entry withstand direct hose-down cleaning — suitable for food-and-bev or automotive body-shop lines where washdown is routine. Operating temperature is -10°C to 40°C, so it's fine for conditioned factory floors but not freezer or outdoor summer extremes without derating.

Frequently asked questions

Will OD2-N120W60I2 drop into a panel specified around OD2-N120W60U2 without rewiring?

Mechanically yes — same chassis mount, same cable leads, same 60-180mm installation distance. Electrically the difference is NPN vs PNP output. If the panel was wired for PNP (sourcing), the NPN output of the I2 variant will not drive the input correctly without rewiring the load connection.

What is the closest functional second-source for OD2-N120W60I2?

The OD2-N120W60U2 is the PNP output sibling — identical form factor, mounting, supply voltage, IP67 rating, and 60-180mm range. The only difference is the output type: NPN on the I2, PNP on the U2.

MPN
OD2-N120W60I2