Skip to main content
SICK OD2-N120W60U0 — Proximity Sensors

OD2-N120W60U0 2D Laser Displacement Sensor, 120mm ±60mm, NPN

MPNOD2-N120W60U0
Active

OD Value series 2D Laser Displacement Sensor, chassis mount, 12~24VDC, NPN output, IP67, 60–180mm installation distance, connector termination.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

OD2-N120W60U0 — Identification
ParameterValue
SeriesOD Value
Type2D Laser Displacement Sensor
OD2-N120W60U0 — Mechanical
ParameterValue
Mounting typeChassis Mount
OD2-N120W60U0 — Environmental
ParameterValue
Operating temperature range-10°C~40°C
OD2-N120W60U0 — Other specifications
ParameterValue
Supply voltage12 ~ 24VDC
Termination styleConnector
IP ratingIP67 - Dust Tight, Waterproof
Installation distance60.0mm ~ 180.0mm

Product details

The OD2-N120W60U0 is a 2D laser displacement sensor from the OD Value series, giving you a 120 mm measurement range with ±60 mm offset from the reference distance. Output is NPN, so it sinks to ground on detection — check your PLC input card polarity before wiring. Installation distance is adjustable from 60.0 mm to 180.0 mm. The sensor runs on 12 to 24 VDC.

Signal integrity and environment

IP67 rating — dust-tight and protected against temporary immersion. That covers washdown zones and dusty conveyor lines, but keep the connector sealed; moisture in the M12 or similar round connector is where failures start. Operating temperature is -10°C to 40°C. If your line runs hot (near ovens or dryers), derate or shield the sensor housing from radiant heat. The laser diode itself is sensitive to ambient above 40°C.

For BOM-freeze planning, this part is a stable line item.

Frequently asked questions

What is the output type on OD2-N120W60U0?

NPN output — it switches the load to ground on detection. Use with sinking-input PLC cards or add a pull-up resistor for PNP-compatible inputs.

Will OD2-N120W60U0 drop into a panel wired for OD2-N120W60I0?

Mechanically and electrically identical — same chassis mount, same connector, same 12–24 VDC supply and IP67 rating. The only difference is the output type: OD2-N120W60I0 is PNP, this one is NPN. Rewire the load side or swap the PLC input card accordingly.

MPN
OD2-N120W60U0