Skip to main content
SICK OD2-N120W60U2 — Proximity Sensors

OD2-N120W60U2 2D Laser Displacement Sensor, NPN, 120mm ±60mm

MPNOD2-N120W60U2
Active

2D Laser Displacement Sensor, OD Value Series, OD2-N120W60U2, NPN output, 120mm ±60mm measurement range, 12-24VDC, IP67, Chassis Mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

OD2-N120W60U2 — Identification
ParameterValue
SeriesOD Value
Type2D Laser Displacement Sensor
OD2-N120W60U2 — Mechanical
ParameterValue
Mounting typeChassis Mount
OD2-N120W60U2 — Environmental
ParameterValue
Operating temperature range-10°C~40°C
OD2-N120W60U2 — Other specifications
ParameterValue
Supply voltage12 ~ 24VDC
Termination styleCable Leads
IP ratingIP67 - Dust Tight, Waterproof
Installation distance60.0mm ~ 180.0mm

Product details

The OD2-N120W60U2 is a 2D laser displacement sensor from the OD Value series, delivering a 120mm measurement range with ±60mm of travel. It outputs an NPN signal, meaning the line goes low when the target is within the sensing window — a common interface for PLC digital inputs that sink current. The 12 to 24 VDC supply range covers standard industrial control voltages, so it runs directly off a 24 VDC panel supply without a separate regulator.

The sensor mounts to a chassis — no DIN-rail adapter included, so plan for a bracket or a direct bolt-down. The IP67 rating means the housing is dust-tight and can survive a temporary water spray; it is suited for washdown zones in food-and-bev lines or for outdoor enclosures where condensation is a risk. The cable leads termination means you are wiring directly into a junction box or connector — no quick-disconnect plug, so factor in the cable length and a strain relief at the panel entry. The installation distance of 60.0mm to 180.0mm defines where the target must sit relative to the sensor face. That is the standoff range over which the laser triangulation stays in focus. If your fixture forces the part closer than 60 mm or farther than 180 mm, this sensor will not give a valid reading — the measurement window is fixed, not adjustable. Operating temperature is -10°C to 40°C. That covers most indoor factory floors but not a freezer or a hot kiln area. If the ambient near the mounting point exceeds 40°C, you need a different sensor or a cooling shield.

Frequently asked questions

What is the measurement range of the OD2-N120W60U2?

The sensor has a 120mm measurement range with ±60mm of travel, and the installation distance (standoff) is 60mm to 180mm from the sensor face.

Will the OD2-N120W60U2 drop into a panel wired for the OD2-N120W60I2?

Yes, the two share identical mechanical and electrical specs — same chassis mount, same 12-24VDC supply, same cable leads, same IP67 housing. The only difference is the output type: the U2 is NPN (sinking), while the I2 is the opposite polarity. If the PLC input card expects a sourcing (PNP) signal, the U2 will not work without a level shifter.

Where can I buy the OD2-N120W60U2 and get current pricing?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a binding price and lead time.

MPN
OD2-N120W60U2