SICK OD Value series, 2D Laser Displacement Sensor, OD2-N250W150U2, 12 ~ 24VDC, 100.0mm ~ 400.0mm installation distance, IP67, cable leads, chassis mount.

$914.40 – $1,450.09Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

OD2-N250W150U2 — Identification
ParameterValue
SeriesOD Value
Type2D Laser Displacement Sensor
OD2-N250W150U2 — Mechanical
ParameterValue
Mounting typeChassis Mount
OD2-N250W150U2 — Environmental
ParameterValue
Operating temperature range-10°C~40°C
OD2-N250W150U2 — Other specifications
ParameterValue
Supply voltage12 ~ 24VDC
Termination styleCable Leads
IP ratingIP67 - Dust Tight, Waterproof
Installation distance100.0mm ~ 400.0mm

Product details

The SICK OD2-N250W150U2 is a 2D laser displacement sensor from the OD Value series, designed for non-contact profile measurement and position detection on production lines. It runs on a 12 ~ 24 VDC supply and delivers a ±150 mm measurement range relative to a nominal standoff of 100.0 mm to 400.0 mm — meaning you can set it up anywhere in that band and get the full ±150 mm window.

The 100.0 mm to 400.0 mm installation distance is the range over which the sensor can be mounted and still output a valid profile — not a fixed focal point. Set it at 250 mm, and you get a ±150 mm measurement window around that. The cable leads termination (no connector) means you'll need to plan for a junction box or a direct gland entry into the panel; the sibling OD2-N250W150U0 and OD2-N250W150I0 use a connector instead, so if your line prefers a quick-disconnect, those are the drop-in swap without rewiring the sensor head. Operating temperature is -10°C to 40°C — fine for a conditioned factory floor but not for an unheated warehouse or outdoor gantry. The IP67 seal keeps dust and water jets out, but the temperature range is the real limiter for cold environments.

Frequently asked questions

Will OD2-N250W150U2 drop into a panel specified around OD2-N250W150A2 without rewiring?

The OD2-N250W150U2 and OD2-N250W150A2 share the same chassis mount footprint, same 12-24 VDC supply, same cable leads termination, and same IP67 rating, so mechanical fit and power wiring are identical. The output signal type may differ — confirm the U2's output matches the A2's before the swap.