Skip to main content
SICK OD2-N30W04A2 — Proximity Sensors

SICK OD2-N30W04A2 2D Laser Displacement Sensor, NPN, 30mm

MPNOD2-N30W04A2
Active

SICK, OD Value series, 2D Laser Displacement Sensor, OD2-N30W04A2, NPN output, 30mm ±4mm range, 12~24VDC, IP67, cable leads.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

OD2-N30W04A2 — Identification
ParameterValue
SeriesOD Value
Type2D Laser Displacement Sensor
OD2-N30W04A2 — Mechanical
ParameterValue
Mounting typeChassis Mount
OD2-N30W04A2 — Environmental
ParameterValue
Operating temperature range-10°C~40°C
OD2-N30W04A2 — Other specifications
ParameterValue
Supply voltage12 ~ 24VDC
Termination styleCable Leads
IP ratingIP67 - Dust Tight, Waterproof
Installation distance26.0mm ~ 34.0mm

Product details

The SICK OD2-N30W04A2 is a 2D laser displacement sensor from the OD Value series, delivering a 30mm measurement range with ±4mm linearity. It outputs an NPN signal, so it pulls the line low when the target is within the detection window — standard for PLC sinking inputs or older controller cards that expect a current-sinking signal. The 12~24VDC supply range covers common industrial power rails without needing a separate regulator. Installation distance is 26.0mm to 34.0mm from the target, so the bracket or fixture needs to hold that standoff within about ±4mm. The cable leads termination means no connector to swap — you wire directly into the control cabinet or junction box, which saves a failure point in high-vibration environments.

Operating temperature and environment

Rated for -10°C to 40°C ambient, so it handles unheated warehouses and conditioned production floors but not freezer tunnels or oven-adjacent stations. If the line runs hot (near ovens, dryers, or foundry areas), you'll need a sensor with a wider thermal range or a cooling shield.

Frequently asked questions

What is the output type on OD2-N30W04A2?

It has an NPN output, meaning it sinks current to ground when the target is detected — compatible with PLCs and controllers expecting a sinking (low-side switching) signal.

What is the measurement range and standoff for this sensor?

The OD2-N30W04A2 has a 30mm measurement range with ±4mm linearity, and the installation distance (standoff) is 26.0mm to 34.0mm from the target surface.

MPN
OD2-N30W04A2