Skip to main content
SICK OD2-N85W20A2 — Proximity Sensors

OD2-N85W20A2 2D Laser Displacement Sensor, NPN Output, IP67

MPNOD2-N85W20A2
Active

OD Value series 2D Laser Displacement Sensor, OD2-N85W20A2, NPN output, 12 ~ 24VDC supply, IP67, cable leads, chassis mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

OD2-N85W20A2 — Identification
ParameterValue
SeriesOD Value
Type2D Laser Displacement Sensor
OD2-N85W20A2 — Mechanical
ParameterValue
Mounting typeChassis Mount
OD2-N85W20A2 — Environmental
ParameterValue
Operating temperature range-10°C~40°C
OD2-N85W20A2 — Other specifications
ParameterValue
Supply voltage12 ~ 24VDC
Termination styleCable Leads
IP ratingIP67 - Dust Tight, Waterproof
Installation distance65.0mm ~ 105.0mm

Product details

The OD2-N85W20A2 is a 2D laser displacement sensor from the OD Value series, delivering an NPN output for profile measurement. It operates from a 12 ~ 24VDC supply and is rated IP67 — dust-tight and protected against water immersion, so it holds up in washdown or outdoor environments without an extra enclosure. The sensor's standoff range is 65.0 mm to 105.0 mm, with a measurement span of ±20 mm around an 85 mm nominal center. That means it reads height, gap, or position profiles across a 40 mm window, which suits part-present verification, weld-seam tracking, or adhesive-bead inspection on a moving line. It is chassis-mounted and terminated with cable leads — no connector to swap, so the wiring is permanent once landed. Operating temperature is -10°C to 40°C, which covers most indoor production floors but not a freezer or foundry without thermal management.

The 65.0 mm to 105.0 mm installation distance is the range over which the sensor achieves its specified ±20 mm measurement window. Mounting closer than 65 mm or farther than 105 mm degrades accuracy or loses the target entirely — the standoff bracket must be set within that band. The chassis-mount form factor bolts directly to a machine frame or a custom bracket; no DIN rail is involved.

Frequently asked questions

Where can I buy OD2-N85W20A2?

The OD2-N85W20A2 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

Will OD2-N85W20A2 drop into a panel specified around OD2-N85W20U2 without rewiring?

Yes — the OD2-N85W20A2 and OD2-N85W20U2 share the same mechanical footprint, mounting, supply voltage, and cable-lead termination. The only difference is the output type: the A2 variant is NPN, while the U2 is PNP. If the panel expects an NPN input, the A2 drops in without rewiring.

What is the measurement range of OD2-N85W20A2?

The sensor has a nominal standoff of 85 mm with a ±20 mm measurement span, and the installation distance range is 65.0 mm to 105.0 mm.

MPN
OD2-N85W20A2