Skip to main content
SICK OD2-N85W20C0 — Proximity Sensors

OD2-N85W20C0 2D Laser Displacement Sensor, 85mm, NPN

MPNOD2-N85W20C0
Active

OD Value series 2D Laser Displacement Sensor, 85mm ±20mm range, NPN output, 12~24VDC, IP67, chassis mount, connector termination.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

OD2-N85W20C0 — Identification
ParameterValue
SeriesOD Value
Type2D Laser Displacement Sensor
OD2-N85W20C0 — Mechanical
ParameterValue
Mounting typeChassis Mount
OD2-N85W20C0 — Environmental
ParameterValue
Operating temperature range-10°C~40°C
OD2-N85W20C0 — Other specifications
ParameterValue
Supply voltage12 ~ 24VDC
Termination styleConnector
IP ratingIP67 - Dust Tight, Waterproof
Installation distance65.0mm ~ 105.0mm

Product details

The OD2-N85W20C0 is a 2D Laser Displacement Sensor from the OD Value series, delivering a 85mm ±20mm measurement range with NPN output. It runs on a 12~24VDC supply and is terminated via connector, making it a drop-in for existing sensor wiring in automated inspection or profiling stations.

The 65.0mm to 105.0mm installation distance means the sensor head must be positioned within that band from the target — not closer, not farther — to maintain the 85mm center range and ±20mm linear window. The IP67 rating (dust-tight, waterproof) allows washdown in food or packaging lines, though the -10°C to 40°C operating temperature range limits it to indoor or climate-controlled outdoor enclosures.

Peer comparison — what changes with the output variant

The OD2-N85W20C0 shares the same mechanical footprint, supply voltage, IP67 rating, and 65–105mm installation distance as siblings OD2-N85W20I0, OD2-N85W20U0, and OD2-N85W20A0. The only difference is the output type: this one is NPN, while the I0 is IO-Link, the U0 is analog voltage, and the A0 is analog current. If your PLC input card expects NPN sinking signals, the C0 is the correct pick; swapping to an IO-Link or analog variant would require a different interface module.

Deployment context

Chassis-mount design with connector termination — no DIN-rail clip, so plan for a bracket or panel cutout. The IP67 rating means it can be mounted directly on a conveyor frame or inspection station without an extra enclosure, as long as the ambient stays within -10°C to 40°C.

Frequently asked questions

Where can I buy OD2-N85W20C0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will OD2-N85W20C0 drop into a panel specified around OD2-N85W20I0 without rewiring?

Physically yes — same chassis mount, same connector, same supply voltage, same IP67 rating. But the output type differs (NPN vs IO-Link), so the PLC input card must support NPN sinking signals. If the original design used IO-Link, rewiring or a converter is needed.

What is the measurement range and installation distance?

The sensor has a 85mm center distance with ±20mm measurement window, and must be installed 65.0mm to 105.0mm from the target.

MPN
OD2-N85W20C0