Skip to main content
SICK OD2-P120W60C2 — Proximity Sensors

OD2-P120W60C2 2D Laser Displacement Sensor, 120mm Range, PNP

MPNOD2-P120W60C2
Active

SICK OD Value series 2D Laser Displacement Sensor, OD2-P120W60C2, 12 ~ 24VDC, PNP output, 60.0mm ~ 180.0mm installation distance, IP67, chassis mount with cable leads.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

OD2-P120W60C2 — Identification
ParameterValue
SeriesOD Value
Type2D Laser Displacement Sensor
OD2-P120W60C2 — Mechanical
ParameterValue
Mounting typeChassis Mount
OD2-P120W60C2 — Environmental
ParameterValue
Operating temperature range-10°C~40°C
OD2-P120W60C2 — Other specifications
ParameterValue
Supply voltage12 ~ 24VDC
Termination styleCable Leads
IP ratingIP67 - Dust Tight, Waterproof
Installation distance60.0mm ~ 180.0mm

Product details

The OD2-P120W60C2 is a 2D laser displacement sensor from the SICK OD Value series, delivering a measurement range of 120mm ±60mm from a reference distance of 60mm to 180mm. That 120mm span means it can profile a part's height or gap variation across a 120mm-wide swath in a single pass — useful for weld-seam tracking, adhesive bead inspection, or component presence verification on a moving line. The PNP output (sourcing) is the common choice for PLC inputs that expect a positive signal; if your card is sinking (NPN), you will need the NPN variant or an interposing relay. The 12 ~ 24VDC supply range is standard for industrial sensors, but the 40°C upper operating temperature limit means you derate if the sensor sits near a drying oven or hot-melt station — the -10°C floor is fine for unheated warehouses.

Deployment context

IP67 rating means the housing and optics survive washdown — suitable for food-and-bev lines, machining coolant splash, or outdoor conveyor gantries provided the cable entry is properly glanded. Chassis mount with cable leads; plan for a strain-relief bracket if the cable sees flex in a robot cell. The 60mm minimum standoff keeps the sensor clear of collision with the target, while the 180mm maximum gives flexibility for varying part heights on the same fixture.

Frequently asked questions

When sourcing OD2-P120W60C2, what's the closest functional second-source — OD2-P120W60U2?

The OD2-P120W60U2 is electrically and mechanically identical — same 12~24VDC supply, same 60-180mm installation distance, same IP67 chassis-mount form factor — but outputs a voltage (analog) signal instead of PNP discrete. If your PLC input card expects a discrete PNP signal, the U2 will not drop in without rewiring the output side. The OD2-P120W60A2 and OD2-P120W60I2 are the other output-variant siblings (analog current and IO-Link, respectively); all share the same footprint and mounting, so the mechanical fit is identical across the four.

What is OD2-P120W60C2's listed type (2D Laser Displacement Sensor) on this component line?

The type is 2D Laser Displacement Sensor. It projects a laser line to measure height profiles across a 120mm width, not a single-point distance.

What is OD2-P120W60C2's listed series (OD Value) on this component line?

The series is OD Value, SICK's compact 2D displacement sensor family designed for inline profile measurement in factory automation.

Will OD2-P120W60C2 drop into a panel that was specified around OD2-P120W60U2 without rewiring?

Mechanically yes — same chassis mount, same cable leads, same 60-180mm installation distance, same IP67 housing. Electrically, the C2 outputs PNP discrete; the U2 outputs a voltage analog signal. If the existing PLC input card is wired for analog voltage, the C2 will not work without rewiring the output to a discrete input. If the card accepts both, confirm the input type and voltage range before swapping.

MPN
OD2-P120W60C2