Skip to main content
SICK OD2-P250W150U2 — Proximity Sensors

OD2-P250W150U2 2D Laser Displacement Sensor, PNP, 100-400mm

MPNOD2-P250W150U2
Active

SICK OD Value series, OD2-P250W150U2, 2D Laser Displacement Sensor, PNP output, 12 ~ 24VDC, 100.0mm ~ 400.0mm installation distance, IP67, cable leads, chassis mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

OD2-P250W150U2 — Identification
ParameterValue
SeriesOD Value
Type2D Laser Displacement Sensor
OD2-P250W150U2 — Mechanical
ParameterValue
Mounting typeChassis Mount
OD2-P250W150U2 — Environmental
ParameterValue
Operating temperature range-10°C~40°C
OD2-P250W150U2 — Other specifications
ParameterValue
Supply voltage12 ~ 24VDC
Termination styleCable Leads
IP ratingIP67 - Dust Tight, Waterproof
Installation distance100.0mm ~ 400.0mm

Product details

The OD2-P250W150U2 is a 2D laser displacement sensor from the SICK OD Value series, delivering a PNP discrete output. It operates on a 12 to 24 VDC supply and covers an installation distance range of 100.0 mm to 400.0 mm. Rated IP67, the sensor body and optics handle washdown environments — suitable for food-and-bev lines or outdoor installations where dust and water jets are present. The operating temperature span of -10°C to 40°C covers most indoor factory-floor conditions, though you'll want to keep it out of direct oven heat or freezer zones.

Integration notes

Chassis-mount form factor with cable leads for termination — plan for a cable gland or strain relief at the panel entry point. The IP67 rating holds as long as the cable entry is sealed. The 100.0 mm to 400.0 mm installation distance is the working range for the 2D profile measurement; the sensor must be mounted within that gap from the target surface. Outside that band, the laser spot defocuses and measurement accuracy drops off.

Frequently asked questions

What is the difference between OD2-P250W150U2 and OD2-P250W150I2?

The OD2-P250W150U2 and OD2-P250W150I2 are functionally identical in type, series, supply voltage, installation distance range, IP rating, and operating temperature. The only difference is the output type: the U2 variant has a PNP output, while the I2 variant has an NPN output. They are not electrically interchangeable without a wiring change.

What is the installation distance range for this sensor?

The OD2-P250W150U2 has an installation distance range of 100.0 mm to 400.0 mm. The sensor must be mounted within that gap from the target surface for accurate 2D profile measurement.

MPN
OD2-P250W150U2