SICK OD2-P30W04C2 2D Laser Displacement Sensor, 30mm ±4mm PN

MPNOD2-P30W04C2
Active

SICK OD Value series, 2D Laser Displacement Sensor, OD2-P30W04C2, 12 ~ 24VDC supply, PNP output, 26.0mm ~ 34.0mm installation distance, IP67, cable leads.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

OD2-P30W04C2 — Identification
ParameterValue
SeriesOD Value
Type2D Laser Displacement Sensor
OD2-P30W04C2 — Mechanical
ParameterValue
Mounting typeChassis Mount
OD2-P30W04C2 — Environmental
ParameterValue
Operating temperature range-10°C~40°C
OD2-P30W04C2 — Other specifications
ParameterValue
Supply voltage12 ~ 24VDC
Termination styleCable Leads
IP ratingIP67 - Dust Tight, Waterproof
Installation distance26.0mm ~ 34.0mm

Product details

The SICK OD2-P30W04C2 is a 2D laser displacement sensor from the OD Value series, delivering a PNP discrete output for presence and position verification within a ±4mm window centered at 30mm. The 26.0mm to 34.0mm installation distance defines the standoff range where the sensor achieves its rated accuracy — mount the target within that band or the measurement falls outside the calibrated field. The 12 ~ 24VDC supply gives you flexibility for common industrial DC rails, but the sensor draws its peak current at the low end; if you're running a 12V bus, confirm the supply can hold regulation under the sensor's inrush. IP67 ingress protection means the housing and cable entry are dust-tight and survive submersion in 1 meter of water for 30 minutes — suitable for washdown zones in food processing or outdoor installations where the sensor sees rain and hose spray.

The OD2-P30W04C2 has an Active lifecycle status. No last-time-buy or phase-out notice is on record.

Peer cross-reference note

The OD2-P30W04C2 shares identical mechanical and electrical specs with the OD2-P30W04U2, OD2-P30W04A2, and OD2-P30W04I2 — same chassis mount, same 12~24VDC supply, same IP67 rating, same 26.0mm to 34.0mm installation distance. The only difference is the output type: the C2 variant outputs PNP, while the U2 is NPN, the A2 is analog, and the I2 is IO-Link. If the panel was wired for an OD2-P30W04U2, the C2 drops into the same footprint and cable termination, but the output logic flips — verify the PLC input card sinks or sources accordingly.

Frequently asked questions

Will OD2-P30W04C2 drop into a panel wired for OD2-P30W04U2?

Yes, the OD2-P30W04C2 shares the same chassis mount, cable leads, and 12~24VDC supply as the OD2-P30W04U2. The difference is output type: the C2 is PNP, the U2 is NPN. No rewiring needed for the connector, but confirm the PLC input card matches the output logic.

What is the installation distance for OD2-P30W04C2?

The OD2-P30W04C2 requires an installation distance of 26.0mm to 34.0mm from the sensor face to the target. The measurement window is ±4mm centered at 30mm.

MPN