Skip to main content
SICK UM12-1172261 — Proximity Sensors

SICK UM12-1172261 Ultrasonic Sensor, 4-20 mA, 20-150 mm

MPNUM12-1172261

SICK UM12 Series, Ultrasonic Sensor, 4...20 mA, 20...150 mm, M12 4-Pin, IP65/IP67.

$293.37 – $358.13Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

UM12-1172261 — Identification
ParameterValue
SeriesUM12
UM12-1172261 — Sensing
ParameterValue
Sensing distance, max.150 mm
UM12-1172261 — Electrical
ParameterValue
Operating voltage, max.30 V
Operating voltage, min.10 V
Termination typeConnector, M12, 4-Pin
UM12-1172261 — Mechanical
ParameterValue
Housing materialBrass Nickel Plated;Polybutylene Terephthalate (PBT)
UM12-1172261 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
IP protection ratingIP65;IP67
UM12-1172261 — Other specifications
ParameterValue
Sensing distance min.20 mm
Ultrasonic sensor output type4 ... 20 mA

Product details

The SICK UM12-1172261 is an ultrasonic sensor from the UM12 series, delivering a 4...20 mA analog output proportional to the distance to the target. It covers a sensing range from 20 mm minimum up to 150 mm maximum, making it suitable for level monitoring, presence detection, or positioning in tight spaces where a short sensing window is needed. The brass nickel-plated housing with PBT sensing face is sealed to IP65/IP67 — fine for washdown zones or outdoor enclosures as long as the M12 connector is properly mated. Termination is via a standard M12 4-pin connector (male), which matches the common sensor interface on most IO-Link masters or analog input modules. No special cable or adapter needed for a typical panel drop.

The closest functional peer in the same UM12 series is UM12-1172211. Same housing, same sensing distance (20-150 mm), same voltage range, same IP rating, same M12 4-pin connector. The only difference is the output: UM12-1172261 gives a 4-20 mA analog signal, while UM12-1172211 switches a PNP discrete output. If your panel was wired for a PNP discrete sensor, the analog output of UM12-1172261 will not drive a digital input — you would need an analog input card or a signal conditioner. The connector pinout is the same, so the mechanical swap is easy, but the wiring and input module must match the analog signal type.

Frequently asked questions

Will UM12-1172261 drop into a panel wired for UM12-1172211 without rewiring?

The M12 4-pin connector is identical, so the mechanical fit and cable plug are the same. However, the analog output (4-20 mA) requires an analog input card, whereas UM12-1172211 expects a PNP digital input. The wiring at the module end must be changed to match the signal type.

MPN
UM12-1172261