Sensor identity and supply constraints
The SICK VL180-P430 is a photoelectric retro-reflective sensor in the VL180 family, supplied at 10 … 30 V DC with a nominal 24 V DC rail. The 2 m cable exits the M18 cylindrical housing — no connector, so the cable entry is fixed at that length; plan the gland plate and conduit drop accordingly if the panel layout demands a shorter pigtail.
Fit considerations against a peer
The VT180-N112 is a photoelectric proximity sensor with NPN output and 130 mm sensing range. The VL180-P430 is retro-reflective with PNP output and relies on a reflector for its beam path.