What this order code actually is
The 1FK2204-6AF00-0MB0 is a SIMOTICS S-1FK2 CT synchronous servo motor in the Siemens 1FK2 family, rated at 1 kW at 3000 rpm on a 380–480 V supply (with a 0.5 kW point at 1500 rpm on a 200–240 V supply) and a 3.2 Nm static torque figure. It pairs directly with SINAMICS S120 drive electronics via the DRIVE-CLiQ M17 feedback connector and the M17 power connector, both of which are integral to this specific -0MB0 variant. The feedback device is an absolute encoder AM22DQC with 22-bit single-turn and 12-bit multi-turn resolution, which means the drive retains absolute position across power cycles without a battery-backed reference run — a direct fit for S120 commissioning where referencing every restart costs cycle time.
Mechanical and environmental envelope
The shaft is cylindrical D19 × 40 mm with an IP64 sealing package. IP64 here means dust-tight and protected against splashing water from any direction, which puts this motor on the factory floor or inside an enclosure — not on a washdown-rated food-and-bev line where IP65 or higher is normally specified. Packaged shipping dimensions of 452.00 x 250.00 x 267.00 mm reflect a single-piece carton, so a single unit ships in one box at the listed quantity unit. Plan panel layout and the inbound receiving dock around this footprint rather than the bare motor body.
Sourcing posture and lifecycle read
Lifecycle is recorded as active and current. Product class is C — manufactured/produced to order, which is the Siemens designation for build-to-order configured items that are not returnable for credit and not reused or re-utilised. Lead-time expectations for class-C lines run longer than catalogue stock lines; the unit is quoted against the BOM quantity, not pulled from a finished-goods shelf. UL/IEC listing details are not in this evidence set.
Commissioning-side check before ordering
Confirm the DRIVE-CLiQ M17 plug, M17 power connector, and AM22DQC encoder resolution on the motor nameplate against the SINAMICS S120 topology in the receiving cabinet. A -0MB0 suffix change in the 1FK2204 frame typically alters the encoder/connector combination, and only the AM22DQC + DRIVE-CLiQ + M17-power configuration here is interchangeable with an existing S120 line-up without a firmware topology re-load.