CT-frame 1FK2 sized for SINAMICS S210 duty
The Siemens 1FK2204-6AF10-2SA0 is a SIMOTICS S-1FK2 CT (compact, high-dynamic) servomotor from the 1FK2 family paired with the SINAMICS S210 drive platform, so it slots in where the converter's motor-side rating is set for a 3.2 Nm stall torque at 3000 rpm. That maps to PN = 1 kW on a 380–480 V line and PN = 0.5 kW on a 200–240 V line at 1500 rpm — the same frame, two bus-voltage windows, which is how the S210 commissioning menu indexes the motor.
What the order-code suffix actually buys
The -6AF10-2SA0 suffix is what distinguishes this variant from a bare 1FK2204: it ships with a holding brake, an absolute encoder single-turn 22-bit AS22DQC, an M17 rotatable plug for the power-and-signal hybrid cable, a cylindrical shaft D14 x 30 mm, and an IP64 housing. The M17 connector and OCC interface combination is the S210 cable family's mating end — a panel builder wiring this against a non-S210 drive will not find the matching pre-assembled cable in the standard catalog.
At 3000 rpm on a 380–480 V supply the continuous output is 1 kW; on a 200–240 V supply, with the speed halved to 1500 rpm, it is 0.5 kW — both are field-weakable via the SINAMICS S210 parameter set, but the published points are the ones the drive wizard asks for during first commissioning. The IP64 rating covers dust and splash from any direction but not pressurised washdown, so the motor lives inside the machine envelope rather than in an exposed food-zone position.
Built-to-order class and what that means for an RFQ
The product is classified as class C: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit — quantity unit is one piece — so a critical-spare order needs to land before the failure, not after, because the motor is not a stocked shelf item that returns on RMA. Lifecycle reads active and current; a holding brake on a CT-frame 1FK2 is the failure mode that takes the line down, so the matching -2SA0 brake variant on the shelf is the spare that gives the cabinet its night back.
Compliance, classification, export gate
Compliance with the substance restrictions according to the RoHS directive has been in force since 01-07-06, and the supplier's REACH Article 33 duty to inform against the current candidate list applies via the linked Reach Information. The motor ships under AL:N / ECCN:N_CNDU export classification — no special export licence gate. Group code R220 and product group 9021 are the internal Siemens classification identifiers a buyer referencing the part on a Siemens document should use as printed.