Active production line — what that means for the BOM
The 1FL2102-2AG01-0MC0: Built-to-order class C on the order code — each unit is produced to the configuration on the PO, so substitutions or returns for credit are not on the menu without an engineering change.
Ratings that decide the panel fit
A 200 V 3AC supply rail feeds a 50 W rated (Pn) low-inertia servomotor with a rated speed (Nn) of 3000 rpm; standstill torque (M0) and rated torque (Mn) both sit at 0.16 Nm, which puts this motor squarely in the small-format positioning axis segment rather than a high-torque machine tool axis. Shaft height 20 mm with a plain shaft (tolerance N) and no holding brake means this unit is intended for an externally-braked or friction-loaded application where the SINAMICS S200 drive handles the stopping energy — for vertical axes the absence of a holding brake is a functional constraint, not just a configurator choice.
Sealing for the deployment environment
IP65 with oil seal at the shaft entry makes the motor body tolerant of coolant mist and cutting-oil splash typical on small-format feed axes, conveyor transfers and packaging lines — the seal rating belongs to the shaft pass-through, not the connector face, so the mating cordset still needs its own sealing plan at the cabinet entry.
Compliance pack on record
RoHS compliance is declared since 01-01-18 and REACH Art. 33 information is published via the manufacturer's reach information file; export control is listed as AL:N / ECCN:N, so the part ships without an export-licensing gate to most destinations.
Procurement posture and ordering
Each unit ships in a single-piece pack (315 x 182 x 172 mm) and is sourced quoted-to-order against the BOM line — the build-to-order class means lead time is configuration-bound rather than a catalog shelf number, so commit the configuration with the RFQ rather than fishing for a same-day ship.