Skip to main content
Siemens 1FL2103-2AF00-1SC0 — Servo Motors

Siemens 1FL2103-2AF00-1SC0 servo motor, 0.2 kW, 400 V, IP54

MPN1FL2103-2AF00-1SC0
Active

Siemens SIMOTICS S-1FL2 low-inertia servomotor, 400 V 3AC, Pn 0.2 kW, Mn 0.64 Nm, Nn 3000 rpm, shaft height 30 mm, IP54, hybrid connector AS21bit, shaft key, tolerance N, without holding brake, for SINAMICS S200.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

1FL2103-2AF00-1SC0 — Identification
ParameterValue
Product family1FL2 servomotors for SINAMICS S200

Approvals

1FL2103-2AF00-1SC0 — Approvals
ParameterValue
RoHS complianceSince: 01-01-18
REACH SVHC declarationReach Information

Other specifications

1FL2103-2AF00-1SC0 — Other specifications
ParameterValue
Group codeR220
Product groupX0DJ
Product classC: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit.
Export control regulationsAL : N / ECCN : N

Product details

What 1FL2103-2AF00-1SC0 is and where it sits

The 1FL2103-2AF00-1SC0 is a SIMOTICS S-1FL2 low-inertia servomotor from the 1FL2 family, sold specifically as the matched servo for the SINAMICS S200 drive line — the motor and drive are paired at order, not mixed-and-matched at panel build. On the nameplate it runs off a 400 V 3AC supply, delivers a rated power of 0.2 kW at a rated speed of 3000 rpm, and holds a continuous rated torque of 0.64 Nm (with a stall torque M0 also at 0.64 Nm, so no pull-up is being claimed on this frame), all on a shaft height of 30 mm — the small frame in the family.

What the mechanical and connector build implies

The shaft carries a shaft key with tolerance N and is built without an oil seal — that's an indoor, clean-side mounting, not a gearbox-end or wet-process spindle. Protection class IP54 covers dust and splashing water but not washdown; the hybrid connector AS21bit carries power and the absolute 21-bit encoder feedback in one shell, so the cabinet-side cable harness lands on a single motor plug rather than separate power and signal leads. This build is supplied without a holding brake — if the axis needs a fail-safe stop under gravity or loss of drive enable, the brake option must be specified on a different variant in the 1FL2 family; do not assume an add-on brake kit retrofits to this order code.

Compliance and substance-restriction posture

Siemens marks the 1FL2103-2AF00-1SC0 as compliant with the RoHS substance restrictions since 01-01-18 and carries the standard REACH Art. 33 duty-to-inform notice on the current candidate list — for a validation pack, this gives you a dated RoHS claim and a defined REACH channel rather than a vendor letter you have to chase down. The product class is coded C — built to order, non-returnable for credit — so a cancellation or quantity adjustment after the order is cut cannot be reversed as a stock return; size the line on the first PO and treat the unit as a make-to-order line item.

Lifecycle and sourcing posture

Packaging is one piece per pack at 315 × 182 × 172 mm, and the unit ships as a single-piece line item — the typical BOM motion is one motor per axis, sourced quoted-to-order against the SINAMICS S200 system order so the drive and motor remain a matched pair on the same commissioning sheet.

Frequently asked questions

How do I get current pricing and availability for 1FL2103-2AF00-1SC0?

No live stock count, lead-time number, or distributor price is carried on this page — every figure is rebuilt at the RFQ stage against the BOM quantity on the SINAMICS S200 system order.

What compliance documentation does Siemens provide for 1FL2103-2AF00-1SC0 (RoHS, REACH, export)?

Siemens marks the part as compliant with RoHS substance restrictions since 01-01-18 and publishes the REACH Art. 33 duty-to-inform statement on the current candidate list. Export classification is AL:N / ECCN:N, so no special export licence applies. For a validation dossier, the RoHS and REACH positions are on the product record rather than something the buyer has to chase as a one-off letter.

Does the 1FL2103-2AF00-1SC0 have a holding brake?

No — this order code is supplied without a holding brake. If the axis needs a fail-safe stop, a different variant in the 1FL2 family with the brake option must be specified; a brake cannot be retrofitted to the 1FL2103-2AF00-1SC0 as ordered.

MPN
1FL2103-2AF00-1SC0