What you're actually mounting
The 1FL2204-2AG00-1MC0: The motor ships with the AM21bit hybrid connector (single-cable feedback + power), a keyed shaft with N tolerance, and no holding brake, sealed to IP54 without an oil seal — so it's the right pick for general industrial cabinet and machine-side mounting where the load isn't held at rest by the motor itself.
Sizing it into the cabinet
Rated 3000 rpm at the 2.4 Nm continuous point means roughly 0.75 kW of usable shaft power on the S200 drive — the matching drive electronics in the SINAMICS S200 family is the pair to commission against, not the older S210 or V90 controller. Shaft height 40 mm keeps the motor in the small-frame S-1FL2 envelope, so any machine bracket sized for a 40 mm S-1FL2 will accept this part without re-machining. Without a holding brake the motor holds position only while the drive is actively delivering torque — vertical axes or gravity-loaded axes need a brake-equipped variant from the same 1FL2 family. The AM21bit hybrid connector is the single-cable variant, so the cabinet side needs the matching Siemens OCC (one-cable) mating connector, not the legacy dual-cable set used on older SIMOTICS motors.
Procurement shape and compliance
Product class C means it's manufactured to order — no shelf-stock return credit, no surplus cancel, lead time and price confirmed against the RFQ rather than pulled from a catalog price list. Quantity unit is one piece, packed one per shipping carton at 382 x 222 x 240 mm. RoHS-compliant since 01-01-18 per the Siemens compliance record, and the part carries the REACH Art. 33 duty-to-inform flag — the candidate-list substance disclosure follows the Siemens Reach Information page, not a per-order document. No ECCN / AL control, so export paperwork is the standard commercial-invoice set.
On the BOM and the RFQ
Active lifecycle stage, made-to-order product class — the realistic path is to quote it on the RFQ with the Group Code R220 and Product Group X0DK on the line so Siemens pricing comes back matched to the variant, not a generic 1FL2 placeholder. Field-engineer reality: this is a small-frame S-1FL2 that's worth pinning to a specific machine BOM before the S200 drive commissioning date, not a last-minute shelf grab.