What this motor is on the BOM
The 1FL2204-4AG01-1HC0 is a SIMOTICS S-1FL2 low-inertia servomotor from Siemens, sized at 1 kW (Pn) with a rated speed of 3000 rpm and a stall/continuous torque of 3.2 Nm (M0 = Mn) on a 40 mm shaft-height frame. The 200 V 3AC supply rating and 17-bit hybrid-connector feedback point it squarely at the SINAMICS S200 drive family listed as the matching drive on the same order code. Group Code R220 and Product Group X0DK are the internal classification strings carried on this order code, which is what the parts catalog uses to keep the motor and its S200 partner aligned on the same BOM line.
Mechanical and connector choices that drive the field install
The shaft is supplied with a key and N-tolerance fit, and the unit ships without a holding brake — so any safety-rated hold on the load has to come from the downstream S200 brake function or a separate mechanical brake on the gearbox. For a panel builder that means the brake option is a deliberate upcharge rather than a default. IP65 with oil seal on a 40 mm shaft-height frame is the right call for a general factory environment but it is not a washdown rating, so food-and-bev or outdoor mounting needs a real IP67/IP67G assessment before this motor lands in the build. The hybrid AS connector carries feedback and power in one shell, which keeps the cable gland count down to one per motor on the panel side.
Production status and what the lifecycle tag means
Packaging is one piece per shipper box at 382.00 x 222.00 x 240.00 mm, which is the shipping footprint the receiving dock should expect when a single motor arrives, not a multi-up pack. Export-control markings are AL:N / ECCN:N, so the part is not subject to a U.S. export license classification on its face.
Compliance paperwork the documentation pack will carry
RoHS compliance is declared since 01-01-18, and the part is flagged under REACH Art. 33 with the standard Reach Information obligation attached, so the decl pack needs the current SVHC candidate-list statement alongside the RoHS line. No additional UL, CSA, or CE marks appear in the order-code data on file — those approvals would need to be pulled from the motor's nameplate or the SINAMICS S200 system documentation at quote time, not assumed from this listing.