Motor ratings and what they mean for your axis
The 1FL6064-1AC61-0AH1: Rated power is 1.5 kW at 2000 rpm rated speed, with a holding torque M0 of 8 Nm and rated torque MN of 7.16 Nm — the holding torque exceeds the rated by about 12 %, giving headroom for acceleration peaks without saturating the magnetic circuit. The incremental TTL encoder delivers 2500 incr/rev — for a 2000 rpm axis that's 83.3 kHz pulse frequency at rated speed, well within the input range of SINAMICS V70 and V90 drives. The plain shaft (tolerance N) accepts standard clamping couplings; no keyway means you verify torque transmission through the clamp fit. IP65 with the included sealing ring — the motor body and shaft seal withstand washdown, but the connector interface (not specified) must be mated with an IP65-rated cable gland to maintain the enclosure rating.
Integration notes for SINAMICS V70/V90 drives
Listed as compatible with SINAMICS V70 and V90 converters — the TTL encoder interface and 400 V 3 AC winding match the drive output stage directly. No external encoder converter needed; the drive's encoder input accepts the 2500-incr TTL signal. The holding brake is factory-integrated — verify the brake voltage and control signal match the drive's brake output card. For a 1.5 kW axis, the brake holds the vertical load at standstill; it is not rated for dynamic braking during motion. Shaft height 65 mm means the motor flange matches standard NEMA 56 frame mounting dimensions — confirm the mounting bolt pattern and pilot diameter against your gearbox or machine interface before ordering.