Skip to main content
Siemens 3RA2110-0ED15-1FB4 — Motor Starters

Siemens 3RA2110-0ED15-1FB4 SIRIUS Motor Starter

MPN3RA2110-0ED15-1FB4
Active

Siemens SIRIUS 3RA2110-0ED15-1FB4 direct-on-line motor starter, size S00, 90 kW at 400 V AC-3, Class 10, for 60 mm busbar systems, screw terminals.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2110-0ED15-1FB4 — Identification
ParameterValue
Product designationDirect (on-line) starter
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructionfor 60 mm busbars
Circuit-breaker sizeS00
Included contactor (type)3RT2015-1FB41
Included circuit-breaker (type)3RV2011-0EA10
Included link module (type)3RA1921-1DA00

Ratings & Performance

3RA2110-0ED15-1FB4 — Ratings & Performance
ParameterValue
Rated motor power at 400 V90 kW
Rated voltage at AC-3, max.690 V
Rated current at 480 V0.4 A
Rated current at 600 V0.4 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V

Protection & Tripping

3RA2110-0ED15-1FB4 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)150 000 A
Overload release setting range (current)0.28 ... 0.4 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2

Contacts & Control

3RA2110-0ED15-1FB4 — Contacts & Control
ParameterValue
Rated value24 ... 24 V
Control supply voltage typeDC
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Communication

3RA2110-0ED15-1FB4 — Communication
ParameterValue
AS-Interface protocol supportNo

Mechanical & Connection

3RA2110-0ED15-1FB4 — Mechanical & Connection
ParameterValue
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width45 mm
Height203 mm
Depth155 mm

Environmental

3RA2110-0ED15-1FB4 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-50 ... +80 °C
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

90 kW at 400 V — SIRIUS S00 direct starter

The 3RA2110-0ED15-1FB4: It ships as a pre-assembled unit: the supplied contactor (3RT2015-1FB41), thermal bimetallic overload relay, and magnetic short-circuit trip are integrated with a link module (3RA1921-1DA00) and a busbar adapter (8US1251-5DS10) for snapping onto 60 mm busbar systems.

Class 10 overload and panel fit

The thermal bimetallic overload is set to Trip Class 10, meaning it protects standard AC induction motors during start-up without nuisance tripping on normal inrush — a common spec for general-purpose motor branches. Dimensions are 155 mm deep, 45 mm wide, 203 mm tall, with a vertical mounting position and clearance requirements of 50 mm upward, 20 mm forward, 20 mm at the side, and 10 mm downward — zero backward clearance needed, so it fits tight against the backplane.

MPN
3RA2110-0ED15-1FB4