Skip to main content
Siemens 3RA2110-0JA15-1AP6 — Motor Starters

Siemens 3RA2110-0JA15-1AP6 SIRIUS Motor Starter, S00

MPN3RA2110-0JA15-1AP6

Siemens SIRIUS 3RA2110-0JA15-1AP6 non-fused motor starter, size S00, direct starter, Class 10 thermal overload, 250 W at 400 V, 45 mm wide, DIN rail or screw mount.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2110-0JA15-1AP6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructiondirect starter
Circuit-breaker sizeS00
Included contactor (type)3RT2015-1AP61
Included circuit-breaker (type)3RV2011-0JA10
Included link module (type)3RA1921-1DA00

Ratings & Performance

3RA2110-0JA15-1AP6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V250 W
Operational current Ie, AC-3 at 400 V0.85 A
Rated voltage at AC-3, max.690 V
Rated motor power at 575/600 V (hp)0.5 hp
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)30 000 000

Protection & Tripping

3RA2110-0JA15-1AP6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)0.7 ... 1 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2

Contacts & Control

3RA2110-0JA15-1AP6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz187 ... 242 V
Auxiliary contacts, NO1
Auxiliary contacts, NC0
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Mechanical & Connection

3RA2110-0JA15-1AP6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12
Mounting / fastening methodSnap-mounted to DIN rail or screw-mounted with additional push-in lug
Mounting positionvertical
Width45 mm
Height167.2 mm
Depth97.1 mm

Environmental

3RA2110-0JA15-1AP6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

SIRIUS 3RA2 direct starter — what ships in the box

The 3RA2110-0JA15-1AP6: This is a Siemens SIRIUS 3RA2 non-fused motor starter, size S00, configured as a direct starter — meaning it combines a contactor and a thermal overload relay in a single, coordinated assembly for switching and protecting a motor load. The supplied contactor is a 3RT2015-1AP61, the link module is a 3RA1921-1DA00, and the circuit-breaker is a 3RV2011-0JA10 — all factory-matched, so you don't need to size the coordination yourself. Rated 250 W at 400 V (50 Hz) and 370 W at 500 V, 550 W at 690 V, with an operating frequency of 50 to 60 Hz. The overload release is thermal bimetallic (Class 10 trip), and the short-circuit trip is magnetic — typical for a compact motor starter protecting a small induction motor.

Mounting and panel fit — DIN or screw

Mounting position is vertical. Dimensions: 45 mm wide, 167.2 mm high, 97.1 mm deep. Clearances: 20 mm upward, 10 mm downward, 9 mm at the side — zero forward or backward. The size S00 footprint means it fits in compact distribution boards or small control panels. The terminal arrangement is standard for size S00; the screw terminals are captive and clearly marked.

Active production — sourcing posture

The supplied subcomponents (contactor, link module, circuit-breaker) are all standard catalog items, so if you already have those in stock you can also order them individually as spares.

Frequently asked questions

What are the power ratings for 3RA2110-0JA15-1AP6 at different voltages?

At 400 V it is rated 250 W, at 500 V 370 W, and at 690 V 550 W. At 575/600 V it is rated 0.5 hp. The coil voltage range is 187 to 242 V at 50 Hz and 192 to 264 V at 60 Hz.

What subcomponents are supplied with the 3RA2110-0JA15-1AP6?

The assembly includes the 3RT2015-1AP61 contactor, the 3RA1921-1DA00 link module, and the 3RV2011-0JA10 circuit-breaker — all factory-coordinated for the S00 size.

MPN
3RA2110-0JA15-1AP6