Skip to main content
Siemens 3RA2110-0JH15-1AP0 — Motor Starters

Siemens 3RA2110-0JH15-1AP0 SIRIUS Direct Starter, S00

MPN3RA2110-0JH15-1AP0
Active

Siemens SIRIUS 3RA2110-0JH15-1AP0 direct-on-line starter, size S00, 0.25 A at 400 V AC-3, Class 10 trip, spring-loaded terminals, for 60 mm busbar systems.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2110-0JH15-1AP0 — Identification
ParameterValue
Product designationDirect (on-line) starter
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructionfor 60 mm busbars
Circuit-breaker sizeS00
Included contactor (type)3RT2015-2AP01
Included circuit-breaker (type)3RV2011-0JA20
Included link module (type)3RA2911-2AA00

Ratings & Performance

3RA2110-0JH15-1AP0 — Ratings & Performance
ParameterValue
Rated motor power at 400 V250 kW
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)0.5 hp
Rated motor power at 575/600 V (hp)0.5 hp
Rated current at 480 V1 A
Rated current at 600 V1 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V

Protection & Tripping

3RA2110-0JH15-1AP0 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)150 000 A
Overload release setting range (current)0.7 ... 1 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2

Contacts & Control

3RA2110-0JH15-1AP0 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz230 ... 230 V
Control supply voltage typeAC
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Communication

3RA2110-0JH15-1AP0 — Communication
ParameterValue
AS-Interface protocol supportNo

Mechanical & Connection

3RA2110-0JH15-1AP0 — Mechanical & Connection
ParameterValue
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width45 mm
Height260 mm
Depth155 mm

Environmental

3RA2110-0JH15-1AP0 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-50 ... +80 °C
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

S00 direct starter on 60 mm busbars

The Siemens 3RA2110-0JH15-1AP0 is a SIRIUS direct-on-line starter in size S00, designed specifically for snapping onto 60 mm busbar systems — a space-saving alternative to DIN-rail mounting when the busbar is the primary distribution backbone. It ships as a pre-assembled unit containing the 3RT2015-2AP01 contactor and the 3RA2911-2AA00 link module, so the BOM line covers the starter function without separate component procurement.

Dimensions and clearance for panel layout

Clearance requirements are specified for vertical mounting: 50 mm upwards, 20 mm forwards, 20 mm at the side, 10 mm downwards, and 0 mm backwards — the zero backward clearance confirms the unit sits flush against the busbar backplane, so no additional rear gap is needed.

Termination, environment, and protocol support

Main current circuit connections use spring-loaded terminals — no screw torque verification needed, which speeds panel wiring and eliminates the risk of loose connections under thermal cycling. Operating temperature range is -20 to +60 °C with temperature compensation active across the same band; storage and transport limits extend from -50 to +80 °C. This covers most indoor industrial environments without derating, though the 60 °C ceiling should be checked against enclosure internal ambient if mounted near heat sources. The starter does not support PROFIsafe or PROFINET IO protocols — it is a conventional hardwired direct starter, not a motor starter with integrated fieldbus communication. For networked applications, a separate communication module or a SIRIUS 3RA6/3RA7 series starter with PROFINET would be required.

Lifecycle and sourcing posture

For audit purposes, the supplied contactor and link module part numbers (3RT2015-2AP01, 3RA2911-2AA00) are documented for traceability against the original equipment specification.

Frequently asked questions

What is the trip class of this starter and what does it mean?

This matches the thermal characteristic of standard squirrel-cage induction motors during a stalled-rotor condition, providing coordinated protection without nuisance tripping during normal starts.

What clearance distances are required around this starter?

For vertical mounting, the required clearances are: 50 mm upwards, 20 mm forwards, 20 mm at the side, 10 mm downwards, and 0 mm backwards. The zero backward clearance means the unit mounts flush against the busbar backplane.

MPN
3RA2110-0JH15-1AP0