Skip to main content
Siemens 3RA2110-1AD15-1AP6 — Motor Starters

Siemens 3RA2110-1AD15-1AP6 SIRIUS Motor Starter, Size S00

MPN3RA2110-1AD15-1AP6

Siemens SIRIUS 3RA2110-1AD15-1AP6 non-fused motor starter, Size S00, direct starter, Class 10 thermal bimetallic overload, 690 V AC-3, 45 mm wide, snap-on 60 mm busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RA2110-1AD15-1AP6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructiondirect starter
Circuit-breaker sizeS00
Included contactor (type)3RT2015-1AP61
Included circuit-breaker (type)3RV2011-1AA10
Included link module (type)3RA1921-1DA00
3RA2110-1AD15-1AP6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V550 W
Operational current Ie, AC-3 at 400 V1.5 A
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)0.75 hp
Rated motor power at 575/600 V (hp)0.75 hp
Rated current at 480 V1.6 A
Rated current at 600 V1.3 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
3RA2110-1AD15-1AP6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)1.1 ... 1.6 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2
3RA2110-1AD15-1AP6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz187 ... 242 V
Auxiliary contacts, NO1
Auxiliary switch extensionYes
Switching contact typeelectromechanical
3RA2110-1AD15-1AP6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width45 mm
Height200 mm
Depth155.1 mm
3RA2110-1AD15-1AP6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

What this SIRIUS 3RA2 direct starter packs — and what it skips

The 3RA2110-1AD15-1AP6 is a Siemens SIRIUS non-fused motor starter — a direct starter that combines a contactor and a thermal overload relay in one Size S00 package, ready to snap onto a 60 mm busbar system without an external fuse holder. It ships as a wired assembly: the supplied contactor is a 3RT2015-1AP61, the link module is 3RA1921-1DA00, and the busbar adapter is 8US1251-5DS10 — so the BOM line is one order code, not three separate picks.

AC-3 duty ceiling and motor sizing across voltages

Rated maximum 690 V in AC-3 duty, so it switches motor loads at 400 V, 480 V, or 600 V line without derating the switching capacity — the contactor's arc extinction handles the full line voltage. At 230 V it's rated 0.1 hp — this starter is sized for fractional-horsepower to about 1.5 hp motors at typical North American line voltages, not for larger loads that would need a Size S2 or S3 frame.

Panel fit — dimensions, mounting, and clearances

Width is 45 mm, depth 155.1 mm, height 200 mm — the 45 mm width matches a standard 45 mm DIN-rail footprint, but the mounting method is snap-on onto 60 mm busbar systems, not a DIN rail, so plan the busbar layout accordingly. Clearance requirements: 20 mm upwards, 10 mm downwards, 9 mm at the side, and zero forwards or backwards — the tight side clearance means adjacent starters can pack closely on the busbar without derating. Mounting position is vertical only — horizontal mounting would change the thermal overload trip curve and is not supported.

Environmental limits and pollution rating

Operating temperature range is -20 to +60 °C, storage -50 to +80 °C, transport -55 to +80 °C — the -20 °C floor means it's usable in unheated enclosures in most temperate climates, but not in deep-freeze or arctic installations without enclosure heating. Degree of pollution 3 means the starter is rated for conductive pollution or dry non-conductive pollution that becomes conductive due to condensation — typical for industrial control panels without climate control, but not for clean-room or hermetically sealed environments.

Coil voltage tolerance and line frequency

The control coil is rated 187-242 V at 50 Hz and 192-264 V at 60 Hz — that's a ±10% tolerance band around the nominal 230 V control supply, so a sagging control transformer or a weak UPS output won't drop the contactor out prematurely. Operating frequency is 50-60 Hz, covering both 50 Hz European and 60 Hz North American line supplies with the same coil — no frequency-specific variant needed.

No stock-holding claim — quoted per order.

Frequently asked questions

What is the 3RA2110-1AD15-1AP6's depth and width for panel planning?

Depth is 155.1 mm, width is 45 mm, height is 200 mm. The 45 mm width fits the standard Size S00 footprint on 60 mm busbar systems. Clearance needed: 20 mm above, 10 mm below, 9 mm at the sides.

MPN
3RA2110-1AD15-1AP6