Siemens 3RA2110-1DD15-1FB4 — Motor Starters

Siemens 3RA2110-1DD15-1FB4 SIRIUS Direct-on-Line Starter

MPN3RA2110-1DD15-1FB4
Active

Siemens SIRIUS 3RA2110-1DD15-1FB4 direct-on-line starter, size S00, 3.2 A AC-3 at 400 V, 24 V DC coil, screw terminals, for 60 mm busbar snap-on mounting.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2110-1DD15-1FB4 — Identification
ParameterValue
Product designationDirect (on-line) starter
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructionfor 60 mm busbars
Circuit-breaker sizeS00
Included contactor (type)3RT2015-1FB41
Included circuit-breaker (type)3RV2011-1DA10
Included link module (type)3RA1921-1DA00

Ratings & Performance

3RA2110-1DD15-1FB4 — Ratings & Performance
ParameterValue
Rated motor power at 400 V1 100 kW
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)2 hp
Rated motor power at 575/600 V (hp)3 hp
Rated current at 480 V3.2 A
Rated current at 600 V3.2 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V

Protection & Tripping

3RA2110-1DD15-1FB4 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)150 000 A
Overload release setting range (current)2.2 ... 3.2 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2

Contacts & Control

3RA2110-1DD15-1FB4 — Contacts & Control
ParameterValue
Rated value24 ... 24 V
Control supply voltage typeDC
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Communication

3RA2110-1DD15-1FB4 — Communication
ParameterValue
AS-Interface protocol supportNo

Mechanical & Connection

3RA2110-1DD15-1FB4 — Mechanical & Connection
ParameterValue
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width45 mm
Height203 mm
Depth155 mm

Environmental

3RA2110-1DD15-1FB4 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-50 ... +80 °C
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

Busbar-mount DOL starter for motor control panels

The 3RA2110-1DD15-1FB4: It snaps onto 60 mm busbar systems using the integral fastening method, eliminating separate DIN-rail adapters and reducing panel wiring time. The supplied contactor is 3RT2015-1FB41 and the link module is 3RA1921-1DA00, meaning the starter ships as a matched assembly with coordinated thermal and magnetic protection. Trip class 10 means it disconnects the motor within 10 seconds under locked-rotor conditions, meeting IEC 60947-4-1 requirements for standard motor starting applications.

Control voltage and terminal wiring

The coil is rated 24 V DC — a common control voltage in PLC-based panels, but verify your control transformer or power supply matches the DC polarity and voltage tolerance. Main current circuit termination uses screw-type terminals, rated for the 3.2 A AC-3 load at up to 690 V maximum. Dimensions are 45 mm wide by 155 mm deep by 203 mm high — the width fits a single 45 mm busbar pitch, so adjacent starters sit without side-to-side clearance issues. Operating temperature range is -20 to +60 °C, with storage and transport tolerance from -50 to +80 °C, so it handles unheated warehouses and trucking in cold climates.

Frequently asked questions

What is the depth of the 3RA2110-1DD15-1FB4?

The depth is 155 mm, with 50 mm clearance required upwards, 20 mm forwards, and 10 mm downwards for ventilation and wiring access.

MPN