Siemens 3RA2110-1FD15-1AP6 — Motor Starters

Siemens 3RA2110-1FD15-1AP6 SIRIUS Motor Starter, S00, 690V

MPN3RA2110-1FD15-1AP6

Siemens SIRIUS 3RA2110-1FD15-1AP6 non-fused motor starter, size S00, direct starter design, 690 V rated, Class 10 thermal overload, supplied with contactor 3RT2015-1AP61 and link module 3RA1921-1DA00.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2110-1FD15-1AP6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructiondirect starter
Circuit-breaker sizeS00
Included contactor (type)3RT2015-1AP61
Included circuit-breaker (type)3RV2011-1FA10
Included link module (type)3RA1921-1DA00

Ratings & Performance

3RA2110-1FD15-1AP6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V1 500 W
Operational current Ie, AC-3 at 400 V3.6 A
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)3 hp
Rated motor power at 575/600 V (hp)3 hp
Rated current at 480 V4.8 A
Rated current at 600 V4.55 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)30 000 000

Protection & Tripping

3RA2110-1FD15-1AP6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)3.5 ... 5 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)1

Contacts & Control

3RA2110-1FD15-1AP6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz187 ... 242 V
Auxiliary contacts, NO1
Auxiliary contacts, NC0
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Mechanical & Connection

3RA2110-1FD15-1AP6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width45 mm
Height200 mm
Depth155.1 mm

Environmental

3RA2110-1FD15-1AP6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

Active production — what it means for the BOM line

The 3RA2110-1FD15-1AP6: It's a SIRIUS-branded non-fused motor starter (direct starter design), size S00, built around a supplied 3RT2015-1AP61 contactor and a 3RA1921-1DA00 link module. The overload release is thermal bimetallic, trip class 10.

Rated power across common line voltages

At 400 V AC-3 it's rated 1500 W; at 460/480 V it's 3 hp. The 690 V maximum rated value (AC-3) covers 600 V class installations without derating the switching capacity. At 230 V it's rated 0.5 hp; at 200/208 V it's 1 hp.

Mounting and panel fit — snaps onto 60 mm busbar

Fastening method is snap-on for 60 mm busbar systems — no DIN rail adapter needed if you're running a busbar grid. Mounting position is vertical only. Dimensions: 45 mm wide, 200 mm tall, 155.1 mm deep. Clearance requirements: 20 mm upwards, 10 mm downwards, 9 mm at the side. The S00 footprint is compact enough for high-density panel layouts. Pollution degree 3 — suitable for industrial environments with conductive dust or condensation.

Operating temperature range -20 to +60 °C; storage -50 to +80 °C; transport -55 to +80 °C. The wide storage range means it can sit on a shelf in an unheated warehouse without issue.

Frequently asked questions

What is the 3RA2110-1FD15-1AP6 rated for at 400 V?

At 400 V AC-3 it's rated 1500 W. The maximum rated voltage is 690 V AC-3, and the trip class is 10 (thermal bimetallic overload).

What contactor and link module are supplied with this motor starter?

It ships with a 3RT2015-1AP61 contactor and a 3RA1921-1DA00 link module, both factory-assembled as a non-fused motor starter unit.

MPN
3RA2110-1FD15-1AP6