Siemens 3RA2110-1HH15-1AP0 — Motor Starters

Siemens 3RA2110-1HH15-1AP0 SIRIUS Motor Starter

MPN3RA2110-1HH15-1AP0
Active

Siemens SIRIUS 3RA2110-1HH15-1AP0 direct-on-line motor starter, size S00, 3 kW at 400 V AC-3, Class 10, spring-loaded terminals, 45 mm wide, snaps onto 60 mm busbar systems.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2110-1HH15-1AP0 — Identification
ParameterValue
Product designationDirect (on-line) starter
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructionfor 60 mm busbars
Circuit-breaker sizeS00
Included contactor (type)3RT2015-2AP01
Included circuit-breaker (type)3RV2011-1HA20
Included link module (type)3RA2911-2AA00

Ratings & Performance

3RA2110-1HH15-1AP0 — Ratings & Performance
ParameterValue
Rated motor power at 400 V3 000 W
Operational current Ie, AC-3 at 400 V6.5 A
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)5 hp
Rated motor power at 575/600 V (hp)5 hp
Rated current at 480 V8 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)30 000 000

Protection & Tripping

3RA2110-1HH15-1AP0 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)150 000 A
Overload release setting range (current)5.5 ... 8 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)1

Contacts & Control

3RA2110-1HH15-1AP0 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz230 ... 230 V
Control supply voltage typeAC
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Communication

3RA2110-1HH15-1AP0 — Communication
ParameterValue
AS-Interface protocol supportNo

Mechanical & Connection

3RA2110-1HH15-1AP0 — Mechanical & Connection
ParameterValue
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width45 mm
Height260 mm
Depth155 mm

Environmental

3RA2110-1HH15-1AP0 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-50 ... +80 °C
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

45 mm wide, snaps onto 60 mm busbars — not DIN rail

The 3RA2110-1HH15-1AP0: This is a busbar-mounted direct-on-line starter, not a DIN-rail unit. The fastening method is for snapping onto 60 mm busbar systems. The supplied busbar adapter is part number 8US1251-5DT11. Width is 45 mm, height 260 mm, depth 155 mm. The 155 mm depth is the dimension that catches panel layouts — it's deeper than a standalone contactor because the overload relay and link module sit behind the contactor on the busbar adapter. Clearance requirements: 50 mm upwards, 20 mm forwards, 10 mm downwards, 20 mm at the side, 0 mm backwards. Mounting position is vertical only.

Rated motor power is 3 000 W at 400 V, 50/60 Hz. At 480 V the rated current is 8 A. This is standard for general-purpose motor starting — not for high-inertia loads like large fans or centrifuges that need Class 20 or 30.

Supplied as a kit — contactor, link module, busbar adapter

The starter ships as a pre-assembled kit: contactor 3RT2015-2AP01, link module 3RA2911-2AA00, and busbar adapter 8US1251-5DT11. The contactor switching contact is electromechanical. Main circuit terminals are spring-loaded — push-in wiring for solid or ferruled stranded conductors. No screw torque to verify, which saves time on repetitive builds. Overload release design is thermal bimetallic. The circuit-breaker size is S00, matching the load feeder size.

Active production — no phase-out signal

Operating temperature range is -20 to +60 °C with temperature compensation across the same range. Storage and transport range is -50 to +80 °C. Substance prohibitance date is 10/01/2009 — the part complies with RoHS substance restrictions as of that date.

Frequently asked questions

What is 3RA2110-1HH15-1AP0's listed depth (155 mm) on this Motor Starters line?

The depth is 155 mm. This is the dimension that most often requires checking in a panel layout — it's deeper than a standalone contactor because the overload relay and link module sit behind the contactor on the busbar adapter.

What is 3RA2110-1HH15-1AP0's listed width (45 mm) on this Motor Starters line?

The width is 45 mm. This is a single-module-wide footprint for a size S00 load feeder that includes the contactor, overload relay, and link module in one assembly.

What compliance documentation does Siemens provide for 3RA2110-1HH15-1AP0 (RoHS, REACH, UL, IEC)?

The substance prohibitance date is 10/01/2009, indicating RoHS compliance as of that date. The product is part of the Siemens SIRIUS brand and carries the standard IEC/EN certifications for the series. Specific UL/CSA documentation is available from Siemens on request.

MPN