Skip to main content
Siemens 3RA2110-4AD18-1AP6 — Motor Starters

Siemens 3RA2110-4AD18-1AP6 Motor Starter, SIRIUS

MPN3RA2110-4AD18-1AP6

Siemens SIRIUS 3RA2110-4AD18-1AP6 non-fused motor starter, direct starter design, size S00, Class 10 thermal overload, 14 A at 480 V, 690 V rated insulation, snaps onto 60 mm busbar systems.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RA2110-4AD18-1AP6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructiondirect starter
Circuit-breaker sizeS00
Included contactor (type)3RT2018-1AP61
Included circuit-breaker (type)3RV2011-4AA10
Included link module (type)3RA1921-1DA00
3RA2110-4AD18-1AP6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V7 500 W
Operational current Ie, AC-3 at 400 V15.5 A
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)10 hp
Rated motor power at 575/600 V (hp)10 hp
Rated current at 480 V14 A
Rated current at 600 V11 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)30 000 000
3RA2110-4AD18-1AP6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)11 ... 16 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)1
3RA2110-4AD18-1AP6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz187 ... 242 V
Auxiliary contacts, NO1
Auxiliary contacts, NC0
Auxiliary switch extensionYes
Switching contact typeelectromechanical
3RA2110-4AD18-1AP6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width45 mm
Height200 mm
Depth155.1 mm
3RA2110-4AD18-1AP6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

Direct starter with Class 10 thermal protection

The 3RA2110-4AD18-1AP6 is a SIRIUS non-fused motor starter in a direct starter design — no reversing contactor, no soft-start logic, just the contactor and overload in one package for simple across-the-line starting. Rated motor power hits 7500 W at 400 V and 10 hp at both 460/480 V and 575/600 V — the 14 A at 480 V and 11 A at 600 V figures tell you the current ceiling in North American 60 Hz applications.

Size S00 footprint on 60 mm busbar

Size S00 load feeder — the smallest SIRIUS frame — keeps the panel width to 45 mm and depth to 155.1 mm, with a total height of 200 mm. Mounts by snapping directly onto 60 mm busbar systems — no DIN rail adapter needed, which saves a row of rail and speeds up assembly in busbar-fed distribution panels. Mounting position is vertical only; clearance above the unit is 20 mm and below is 10 mm, with 9 mm to the side — tight enough for dense busbar layouts but plan the 20 mm upward for heat rise from the bimetallic element.

Integrated contactor and link module included

Ships with the 3RT2018-1AP61 contactor and 3RA1921-1DA00 link module already assembled — one order code, one stock-keeping unit, no separate contactor and overload to match. The supplied contactor handles the AC-3 switching duty up to 690 V; the link module connects the overload output to the contactor coil circuit so the starter drops out on overload without auxiliary wiring. For the MRO storeroom, this is a fast mover — one line item replaces three separate part numbers (contactor, overload relay, link), simplifying the min/max stock level.

Volume pricing and lead time confirmed at RFQ. The 3RA2110-4AD18-1AP6 is a standard catalog item under the SIRIUS brand — no special lead-time risk for project builds or MRO spares.

Frequently asked questions

What are the key ratings for 3RA2110-4AD18-1AP6?

Rated insulation voltage 690 V, AC-3 rated voltage maximum 690 V. Motor power: 7500 W at 400 V, 10 hp at 460/480 V and 575/600 V. Current: 14 A at 480 V, 11 A at 600 V. Trip Class 10 thermal overload. Size S00, snaps onto 60 mm busbar.

MPN
3RA2110-4AD18-1AP6