Siemens 3RA2115-0FA15-1AK6 — Motor Starters

Siemens 3RA2115-0FA15-1AK6 SIRIUS Non-Fused Motor Starter

MPN3RA2115-0FA15-1AK6

Siemens SIRIUS 3RA2115-0FA15-1AK6 non-fused motor starter, direct starter, frame size S00, 120 W at 400 V, Class 10, snap-on DIN rail or screw mount.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2115-0FA15-1AK6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructiondirect starter
Circuit-breaker sizeS00
Included contactor (type)3RT2015-1AK61
Included circuit-breaker (type)3RV2011-0FA15
Included link module (type)3RA1921-1DA00

Ratings & Performance

3RA2115-0FA15-1AK6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V120 W
Operational current Ie, AC-3 at 400 V0.4 A
Rated voltage at AC-3, max.690 V
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)30 000 000

Protection & Tripping

3RA2115-0FA15-1AK6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)0.35 ... 0.5 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2

Contacts & Control

3RA2115-0FA15-1AK6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz93.5 ... 121 V
Auxiliary contacts, NO2
Auxiliary contacts, NC1
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Mechanical & Connection

3RA2115-0FA15-1AK6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12
Mounting / fastening methodSnap-mounted to DIN rail or screw-mounted with additional push-in lug
Mounting positionvertical
Width45 mm
Height167.2 mm
Depth97.1 mm

Environmental

3RA2115-0FA15-1AK6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

Panel fit and mounting flexibility

The 3RA2115-0FA15-1AK6: Snap-mounted to DIN rail or screw-mounted with an additional push-in lug — the S00 frame fits standard 45 mm wide slots in a panel layout. Mounting position is vertical with 20 mm clearance upward and 10 mm downward; zero clearance needed forward or backward, so adjacent components can butt directly against the body. Overall dimensions: 167.2 mm height, 45 mm width, 97.1 mm depth — fits a standard S00 feeder footprint without surprises.

Motor protection and trip coordination

Thermal bimetallic overload release paired with a magnetic short-circuit trip gives two-stage protection: the bimetal tracks motor heating, the magnetic element clears a hard fault instantly. Rated operational voltage up to 690 V AC at AC-3 duty, operating frequency 50/60 Hz — covers most low-voltage motor circuits in European and North American panels.

Supplied sub-assemblies and wire terminations

This direct starter ships with the contactor 3RT2015-1AK61, the link module 3RA1921-1DA00, and the circuit-breaker 3RV2011-0FA15 — three matched components in one order code, no separate sourcing. AWG sizes from 2× 20 to 2× 12, with 2× (18 to 14) for the contactor side. An auxiliary switch expansion slot is built into the product extension, so adding feedback contacts or status signals doesn't require a separate enclosure.

Environmental and compliance envelope

Pollution degree 3 per IEC 60947-1, meaning it tolerates conductive dust and condensation typical in industrial control panels without conformal coating. Rated impulse withstand voltage 6 kV — coordinates with standard surge protection devices at the panel incoming supply.

Frequently asked questions

What is the rated power output of 3RA2115-0FA15-1AK6 at 400 V?

These are the motor power ratings for the direct starter in AC-3 duty.

MPN
3RA2115-0FA15-1AK6