Skip to main content
Siemens 3RA2115-0FA15-1AP6 — Motor Starters

Siemens 3RA2115-0FA15-1AP6 SIRIUS Motor Starter, Size S00

MPN3RA2115-0FA15-1AP6

Siemens SIRIUS 3RA2115-0FA15-1AP6 non-fused motor starter, direct starter design, Size S00, Class 10, 120 W at 400 V, 45 mm width, snap-on DIN rail mount.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2115-0FA15-1AP6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructiondirect starter
Circuit-breaker sizeS00
Included contactor (type)3RT2015-1AP61
Included circuit-breaker (type)3RV2011-0FA15
Included link module (type)3RA1921-1DA00

Ratings & Performance

3RA2115-0FA15-1AP6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V120 W
Operational current Ie, AC-3 at 400 V0.4 A
Rated voltage at AC-3, max.690 V
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)30 000 000

Protection & Tripping

3RA2115-0FA15-1AP6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)0.35 ... 0.5 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2

Contacts & Control

3RA2115-0FA15-1AP6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz187 ... 242 V
Auxiliary contacts, NO2
Auxiliary contacts, NC1
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Mechanical & Connection

3RA2115-0FA15-1AP6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12
Mounting / fastening methodSnap-mounted to DIN rail or screw-mounted with additional push-in lug
Mounting positionvertical
Width45 mm
Height167.2 mm
Depth97.1 mm

Environmental

3RA2115-0FA15-1AP6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

Panel fit and mounting constraints for the 3RA2115-0FA15-1AP6

This SIRIUS non-fused motor starter snaps onto a DIN rail or can be screw-mounted with an additional push-in lug, giving the panel builder a choice of fastening method depending on the enclosure layout. The unit is 45 mm wide, 167.2 mm tall, and 97.1 mm deep, which fits a standard Size S00 footprint and leaves 20 mm clearance above, 10 mm below, and 9 mm at the side for heat dissipation and wiring access. Mounting position must be vertical per the specification, and the ambient operating range is -20 to +60 °C, with storage from -50 to +80 °C.

Motor protection and trip coordination

The starter is a direct-on-line design with a thermal bimetallic overload relay (Class 10) and a magnetic short-circuit release, which together provide coordinated motor protection in a single assembly. It is rated for AC-3 duty at up to 690 V, with a motor power rating of 120 W at 400 V, 180 W at 500 V, and 250 W at 690 V — the matching power depends on the line voltage at the installation. The supplied contactor is a 3RT2015-1AP61, and the supplied circuit breaker is a 3RV2011-0FA15, forming a fully coordinated starter combination that is factory-tested for selectivity. Pollution degree 3 and a rated surge voltage resistance of 6 kV mean the unit is suitable for industrial environments where transient overvoltages are common.

Coil voltage selection and wiring

The control coil is designed for 50/60 Hz operation, accepting 187–242 V at 50 Hz and 192–264 V at 60 Hz — confirm the supply frequency matches the control transformer tap before energising. The supplied link module (3RA1921-1DA00) interconnects the contactor and circuit breaker, reducing wiring time and eliminating point-to-point errors on the line side.

The auxiliary switch extension option (Product Extension Auxiliary Switch: Yes) means the starter can be kitted with add-on contact blocks for status feedback without a separate wiring harness.

Frequently asked questions

What is the 3RA2115-0FA15-1AP6 rated for at 400 V?

At 400 V AC-3 duty, the motor power rating is 120 W. The unit also carries ratings of 180 W at 500 V and 250 W at 690 V.

MPN
3RA2115-0FA15-1AP6