Skip to main content
Siemens 3RA2115-0HA15-1AP6 — Motor Starters

Siemens 3RA2115-0HA15-1AP6 SIRIUS Motor Starter

MPN3RA2115-0HA15-1AP6

Siemens SIRIUS 3RA2 non-fused motor starter, 3RA2115-0HA15-1AP6, size S00, 180 W at 400 V, Class 10, 3-pole, snap-on DIN rail.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2115-0HA15-1AP6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructiondirect starter
Circuit-breaker sizeS00
Included contactor (type)3RT2015-1AP61
Included circuit-breaker (type)3RV2011-0HA15
Included link module (type)3RA1921-1DA00

Ratings & Performance

3RA2115-0HA15-1AP6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V180 W
Operational current Ie, AC-3 at 400 V0.6 A
Rated voltage at AC-3, max.690 V
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V

Protection & Tripping

3RA2115-0HA15-1AP6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)0.55 ... 0.8 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2

Contacts & Control

3RA2115-0HA15-1AP6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz187 ... 242 V
Auxiliary contacts, NO2
Auxiliary contacts, NC1
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Mechanical & Connection

3RA2115-0HA15-1AP6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Mounting / fastening methodSnap-mounted to DIN rail or screw-mounted with additional push-in lug
Mounting positionvertical
Width45 mm
Height167.2 mm
Depth97.1 mm

Environmental

3RA2115-0HA15-1AP6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

Motor power and trip class

The 3RA2115-0HA15-1AP6: Rated motor power is 180 W at 400 V, 250 W at 500 V, and 370 W at 690 V — these are AC-3 switching values for standard three-phase induction motors. The short-circuit trip is magnetic (instantaneous), and the unit includes a supplied circuit-breaker (3RV2011-0HA15) and contactor (3RT2015-1AP61) integrated via a link module (3RA1921-1DA00). This is a direct starter — no reversing or star-delta — for simple on/off motor control. Surge voltage withstand is 6 kV, and the operating frequency is 50/60 Hz. Coil voltage is 187–242 V at 50 Hz and 192–264 V at 60 Hz — a wide-range coil that covers 200–240 VAC supplies without a tap change.

Mounting and panel fit

Snap-mounts onto 35 mm DIN rail or screws in place with an additional push-in lug. Mounting position is vertical. Dimensions: 45 mm wide, 97.1 mm deep, 167.2 mm high — size S00 footprint. Clearance needed: 20 mm upward, 10 mm downward, 9 mm at the sides, 0 mm forward or backward. Operating temperature range is -20 to +60 °C; storage range is -50 to +80 °C. Pollution degree 3 (industrial environment with conductive or dry non-conductive pollution).

Frequently asked questions

What is the motor power rating of 3RA2115-0HA15-1AP6 at 400 V?

Rated motor power is 180 W at 400 V AC-3 duty. The unit also delivers 250 W at 500 V and 370 W at 690 V.

MPN