Siemens 3RA2115-1ED15-1AP6 — Motor Starters

Siemens 3RA2115-1ED15-1AP6 SIRIUS non-fused motor starter

MPN3RA2115-1ED15-1AP6

Siemens SIRIUS non-fused motor starter 3RA2, size S00, direct starter, Class 10 trip, 690 V rated, for snapping onto 60 mm busbar systems.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2115-1ED15-1AP6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructiondirect starter
Circuit-breaker sizeS00
Included contactor (type)3RT2015-1AP61
Included circuit-breaker (type)3RV2011-1EA15
Included link module (type)3RA1921-1DA00

Ratings & Performance

3RA2115-1ED15-1AP6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V1 500 W
Operational current Ie, AC-3 at 400 V3.6 A
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)2 hp
Rated motor power at 575/600 V (hp)3 hp
Rated current at 480 V3.95 A
Rated current at 600 V4 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)30 000 000

Protection & Tripping

3RA2115-1ED15-1AP6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)2.8 ... 4 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2

Contacts & Control

3RA2115-1ED15-1AP6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz187 ... 242 V
Auxiliary contacts, NO2
Auxiliary contacts, NC1
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Mechanical & Connection

3RA2115-1ED15-1AP6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width45 mm
Height200 mm
Depth155.1 mm

Environmental

3RA2115-1ED15-1AP6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

What this SIRIUS starter brings to a panel

The Siemens 3RA2115-1ED15-1AP6 is a non-fused direct motor starter from the SIRIUS 3RA2 family, size S00, combining a contactor and a thermal bimetallic overload relay in one assembly. The unit ships with a 3RT2015-1AP61 contactor and a 3RA1921-1DA00 link module pre-assembled; the overload release is thermal bimetallic, adjustable to the motor FLA. For the 480 V line, the starter is rated at 3.95 A (2 hp); at 600 V it carries 4 A (3 hp). At 400 V it handles 1 500 W. These are AC-3 motor-switching ratings, so the part is sized for the load, not the bus.

The starter snaps onto 60 mm busbar systems — the standard metric spacing for IEC distribution panels. That means it drops into the same footprint as other S00 load feeders without extra brackets. Mounting position is vertical only; the enclosure dimensions are 200 mm high by 45 mm wide by 155.1 mm deep. Clearance requirements: 20 mm upward, 10 mm downward, 9 mm to the side, and zero forward or backward. That 45 mm width is a single modular unit — no need to gut the existing layout to fit it in.

Coordination and environmental limits

The starter is designed for type of assignment 2 coordination (Type 2 — no damage to the starter under short-circuit conditions up to the rated SCCR). Operating temperature range is -20 to +60 °C; storage range is -50 to +80 °C; transport range is -55 to +80 °C. The main circuit wiring accepts 0.5 to 4 mm² stranded, or 2x 0.75 to 2.5 mm².

Frequently asked questions

What is the trip class of 3RA2115-1ED15-1AP6?

The trip class is CLASS 10, meaning the overload relay will trip within 10 seconds at locked-rotor current. This is the standard trip class for general-purpose induction motor starting.

Is 3RA2115-1ED15-1AP6 compatible with 60 mm busbar systems?

Yes, the fastening method is specifically for snapping onto 60 mm busbar systems — the standard metric spacing used in IEC distribution panels. No adapter brackets are needed.

MPN
3RA2115-1ED15-1AP6