Siemens SIRIUS 3RA2115-4AA18-1AK6 non-fused motor starter, size S00, direct starter, 7.5 kW at 400 V, Class 10, snap-on DIN rail mount, 45 x 167.2 x 97.1 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RA2115-4AA18-1AK6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructiondirect starter
Circuit-breaker sizeS00
Included contactor (type)3RT2018-1AK61
Included circuit-breaker (type)3RV2011-4AA15
Included link module (type)3RA1921-1DA00
3RA2115-4AA18-1AK6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V7 500 W
Operational current Ie, AC-3 at 400 V15.5 A
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)10 hp
Rated motor power at 575/600 V (hp)10 hp
Rated current at 480 V14 A
Rated current at 600 V11 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)30 000 000
3RA2115-4AA18-1AK6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)11 ... 16 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)1
3RA2115-4AA18-1AK6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz93.5 ... 121 V
Auxiliary contacts, NO2
Auxiliary contacts, NC1
Auxiliary switch extensionYes
Switching contact typeelectromechanical
3RA2115-4AA18-1AK6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12
Mounting / fastening methodSnap-mounted to DIN rail or screw-mounted with additional push-in lug
Mounting positionvertical
Width45 mm
Height167.2 mm
Depth97.1 mm
3RA2115-4AA18-1AK6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

Panel fit and mounting — S00 frame on DIN rail

The 3RA2115-4AA18-1AK6 is a non-fused motor starter from the SIRIUS 3RA2 family, size S00. Mounting position is vertical. Clearance needs: 20 mm upward, 10 mm downward, 9 mm at the sides, zero forward or backward — useful for tight panel layouts where gland plates or busbars limit space.

Motor duty and trip class — what the ratings mean

At 400 V AC-3 duty it handles 7.5 kW (10 hp); at 460/480 V it handles 10 hp, and at 575/600 V also 10 hp. The supplied contactor is a 3RT2018-1AK61, and the link module is 3RA1921-1DA00 — the starter ships as a matched assembly, not loose components.

Environmental range and pollution tolerance

Operates from -20 to +60 °C ambient; stores from -50 to +80 °C and survives transport from -55 to +80 °C. Pollution degree 3 means it tolerates conductive dust and condensation typical of industrial enclosures without conformal coating.