Skip to main content
Siemens 3RA2120-0GD23-0AK6 — Motor Starters

Siemens 3RA2120-0GD23-0AK6 SIRIUS Motor Starter

MPN3RA2120-0GD23-0AK6

Siemens SIRIUS 3RA2120-0GD23-0AK6 non-fused motor starter, direct starter, S0 size, 180 W at 400 V, Class 10, 690 V rated, 50/60 Hz.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RA2120-0GD23-0AK6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS0
Product design / constructiondirect starter
Circuit-breaker sizeS00
Included contactor (type)3RT2023-1AK60
Included circuit-breaker (type)3RV2011-0GA10
Included link module (type)3RA2921-1AA00
3RA2120-0GD23-0AK6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V180 W
Operational current Ie, AC-3 at 400 V0.6 A
Rated voltage at AC-3, max.690 V
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)10 000 000
3RA2120-0GD23-0AK6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)0.45 ... 0.63 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2
3RA2120-0GD23-0AK6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz88 ... 121 V
Auxiliary contacts, NO1
Auxiliary contacts, NC1
Auxiliary switch extensionYes
Switching contact typeelectromechanical
3RA2120-0GD23-0AK6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (16 ... 12), 2x (14 ... 8)
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width45 mm
Height260 mm
Depth155 mm
3RA2120-0GD23-0AK6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

Active SIRIUS non-fused motor starter, S0 frame

The 3RA2120-0GD23-0AK6: The unit snaps onto 60 mm busbar systems in a vertical mounting position, integrating directly into a panel without additional brackets.

Supplied subassemblies and wiring capacity

This starter ships with a 3RT2023-1AK60 contactor, a 3RA2921-1AA00 link module, a 3RV2011-0GA10 circuit breaker, and an 8US1251-5NT10 busbar adapter — all factory-matched for the S0/S00 frame combination. Main contact wiring accepts 1 to 10 mm² stranded or 2x (2.5 to 6 mm²), with AWG equivalents of 2x (16 to 12) or 2x (14 to 8). The control coil is rated 88 to 121 V at 50 Hz and 96 to 132 V at 60 Hz, covering standard 110 V control circuits.

Envelope and clearance for panel layout

Dimensions are 155 mm depth, 45 mm width, and 260 mm height — the 45 mm width fits a standard 45 mm DIN-rail pitch, leaving room for adjacent feeders. Required clearances: 30 mm upwards, 10 mm forwards, 10 mm downwards, 9 mm at the side, and 0 mm backwards — the zero backward clearance means it can sit flush against a backplane.

Frequently asked questions

What is the 3RA2120-0GD23-0AK6 used for?

It is a non-fused direct motor starter for controlling and protecting three-phase motors up to 180 W at 400 V or 250 W at 690 V, with a Class 10 thermal overload characteristic. Typical applications include conveyors, pumps, and fans in industrial control panels.

How do I get pricing and availability for the 3RA2120-0GD23-0AK6?

Submit an RFQ through this listing.

MPN
3RA2120-0GD23-0AK6