Siemens 3RA2120-1BA23-0AK6 — Motor Starters

Siemens 3RA2120-1BA23-0AK6 Motor Starter, 750 W at 400 V

MPN3RA2120-1BA23-0AK6

Siemens SIRIUS 3RA2120-1BA23-0AK6 non-fused direct motor starter, 750 W at 400 V AC-3, Class 10 thermal bimetallic overload, S0 size, 45 mm width, 97.1 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RA2120-1BA23-0AK6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS0
Product design / constructiondirect starter
Circuit-breaker sizeS00
Included contactor (type)3RT2023-1AK60
Included circuit-breaker (type)3RV2011-1BA10
Included link module (type)3RA2921-1AA00
3RA2120-1BA23-0AK6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V750 W
Operational current Ie, AC-3 at 400 V1.9 A
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)0.75 hp
Rated motor power at 575/600 V (hp)1 hp
Rated current at 480 V1.63 A
Rated current at 600 V1.72 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)10 000 000
3RA2120-1BA23-0AK6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)1.4 ... 2 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2
3RA2120-1BA23-0AK6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz88 ... 121 V
Auxiliary contacts, NO1
Auxiliary contacts, NC1
Auxiliary switch extensionYes
Switching contact typeelectromechanical
3RA2120-1BA23-0AK6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (16 ... 12), 2x (14 ... 8)
Mounting / fastening methodSnap-mounted to DIN rail or screw-mounted with additional push-in lug
Mounting positionvertical
Width45 mm
Height193.1 mm
Depth97.1 mm
3RA2120-1BA23-0AK6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

750 W at 400 V — what the AC-3 rating means for the motor branch

The 3RA2120-1BA23-0AK6: That 750 W figure at 400 V is the continuous motor power the starter can handle under normal starting and running conditions, provided the upstream short-circuit protection is coordinated for the S0 feeder size. This is the standard class for general-purpose motor starting — it lets the motor accelerate through the inrush without nuisance tripping, provided the start time stays under the 10-second ceiling.

Mounting and panel fit — S0 footprint on DIN rail or screw-fixed

The vertical mounting position is specified; horizontal or inverted mounting would shift the thermal overload calibration and is not supported without a derating check. The S0 feeder size (45 mm wide, 97.1 mm deep, 193.1 mm tall) matches the standard S0 contactor/circuit-breaker footprint — it occupies one 45 mm slot on the rail, leaving 30 mm clearance upward and 10 mm forward/downward for wiring and heat dissipation. The supplied contactor is a 3RT2023-1AK60, and the link module is 3RA2921-1AA00 — these are the factory-matched pair that give the starter its coordinated Type 2 protection profile. If you are replacing a failed unit in an existing panel, confirm that the replacement carries the same supplied contactor order code; swapping in a different contactor variant changes the coordination and voids the UL/IEC listing for the assembly.

Active production — sourcing posture for the BOM line

Operating ambient range is -20 to +60 °C, storage -50 to +80 °C, transport -55 to +80 °C. The thermal overload calibration is referenced to 40 °C ambient; above that, the trip current must be derated per the SIRIUS application manual. Pollution degree 3 (conductive pollution) means this starter is suitable for control panels in industrial environments where occasional condensation or light dust is present.

Frequently asked questions

What compliance documentation does Siemens provide for 3RA2120-1BA23-0AK6?

The SIRIUS 3RA2 series carries IEC/EN 60947-4-1 compliance for motor starters. The specific approvals (UL, CSA, CE, UKCA, EAC) are listed on the Siemens Industry Online Support page for this order code. RoHS and REACH declarations are available through the Siemens declaration-of-conformity portal using the 3RA2120-1BA23-0AK6 order code.

MPN
3RA2120-1BA23-0AK6