Siemens 3RA2120-1BA23-0BB4 — Motor Starters

Siemens 3RA2120-1BA23-0BB4 SIRIUS Motor Starter

MPN3RA2120-1BA23-0BB4

Siemens SIRIUS 3RA2120-1BA23-0BB4 non-fused direct motor starter, size S0, 750 W at 400 V AC-3, Class 10 thermal bimetallic overload, 24 V DC coil, 3RT2023-1BB40 contactor, 3RA2921-1BA00 link module, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RA2120-1BA23-0BB4 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS0
Product design / constructiondirect starter
Circuit-breaker sizeS00
Included contactor (type)3RT2023-1BB40
Included circuit-breaker (type)3RV2011-1BA10
Included link module (type)3RA2921-1BA00
3RA2120-1BA23-0BB4 — Ratings & Performance
ParameterValue
Rated motor power at 400 V750 W
Operational current Ie, AC-3 at 400 V1.9 A
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)0.75 hp
Rated motor power at 575/600 V (hp)1 hp
Rated current at 480 V1.63 A
Rated current at 600 V1.72 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)10 000 000
3RA2120-1BA23-0BB4 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)1.4 ... 2 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2
3RA2120-1BA23-0BB4 — Contacts & Control
ParameterValue
Rated value24 V
Auxiliary contacts, NO1
Auxiliary contacts, NC1
Auxiliary switch extensionYes
Switching contact typeelectromechanical
3RA2120-1BA23-0BB4 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (16 ... 12), 2x (14 ... 8)
Mounting / fastening methodSnap-mounted to DIN rail or screw-mounted with additional push-in lug
Mounting positionvertical
Width45 mm
Height193.1 mm
Depth107 mm
3RA2120-1BA23-0BB4 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

S0 frame, Class 10 — the overload protection that sets the starting duty

The 3RA2120-1BA23-0BB4: The supplied contactor is a 3RT2023-1BB40, and the link module is 3RA2921-1BA00 — these are the integrated assembly that carries the main current path and the control wiring interface.

Panel fit — DIN rail snap-mount and the clearance envelope

Size S0 load feeder with a size S00 circuit-breaker: the starter body measures 45 mm wide, 193.1 mm high, and 107 mm deep — the width is the critical panel-space dimension, fitting a standard 45 mm slot on a DIN rail. Snap-mounts onto a DIN rail or can be screw-mounted with an additional push-in lug — vertical mounting position only, per the spec, so plan the rail orientation accordingly. Clearance distances: 30 mm upwards, 10 mm forwards, 10 mm downwards, 9 mm at the side, 0 mm backwards — these are the minimum air gaps to adjacent metalwork or enclosure walls for heat dissipation and arc flash containment. Main contact wiring accepts stranded conductors 1–10 mm² (single) or 2x 2.5–6 mm², with AWG equivalents 2x 16–12 or 2x 14–8 — sufficient for the 750 W motor circuit without over-specifying the lug.

Motor sizing across line voltages — matching the starter to the load

At 400 V rated value the starter is sized for 750 W; at 500 V it also delivers 750 W, and at 690 V it steps up to 1 100 W — the power rating climbs with voltage because the current limit stays within the contactor's thermal capacity. Operating frequency is 50/60 Hz — the same unit works on 50 Hz European or 60 Hz North American lines without derating.

Lifecycle and compliance — active production, RoHS/REACH dated

Substance prohibitance date is 03/01/2017 — this marks the RoHS/REACH compliance baseline; the starter meets the EU substance restrictions in effect from that date. Degree of pollution 3 means the unit is rated for industrial environments with conductive pollution or dry non-conductive pollution that becomes conductive due to condensation — standard for an unsealed panel-mounted starter.

Frequently asked questions

What motor power does the 3RA2120-1BA23-0BB4 handle at 400 V?

At 400 V AC-3 duty it is rated for 750 W. At 690 V the rating increases to 1 100 W.