Siemens 3RA2120-1BD23-0AP6 SIRIUS Motor Starter

MPN3RA2120-1BD23-0AP6

Siemens SIRIUS 3RA2120-1BD23-0AP6 non-fused motor starter, direct starter, Size S0, 750 W at 400 V AC-3, Class 10 thermal overload, 45 mm width, 155 mm depth, 260 mm height.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RA2120-1BD23-0AP6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS0
Product design / constructiondirect starter
Circuit-breaker sizeS00
Included contactor (type)3RT2023-1AP60
Included circuit-breaker (type)3RV2011-1BA10
Included link module (type)3RA2921-1AA00
3RA2120-1BD23-0AP6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V750 W
Operational current Ie, AC-3 at 400 V1.9 A
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)0.75 hp
Rated motor power at 575/600 V (hp)1 hp
Rated current at 480 V1.63 A
Rated current at 600 V1.72 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)10 000 000
3RA2120-1BD23-0AP6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)1.4 ... 2 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2
3RA2120-1BD23-0AP6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz176 ... 242 V
Auxiliary contacts, NO1
Auxiliary contacts, NC1
Auxiliary switch extensionYes
Switching contact typeelectromechanical
3RA2120-1BD23-0AP6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (16 ... 12), 2x (14 ... 8)
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width45 mm
Height260 mm
Depth155 mm
3RA2120-1BD23-0AP6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

SIRIUS 3RA2 direct starter — panel fit and motor protection

The 3RA2120-1BD23-0AP6 is a non-fused direct starter from the Siemens SIRIUS 3RA2 family, combining a contactor and a thermal bimetallic overload relay in one S0-size package. The supplied contactor is the 3RT2023-1AP60, and the link module 3RA2921-1AA00 ties the contactor and overload together. The busbar adapter 8US1251-5NT10 is included for snapping onto 60 mm busbar systems. Rated operational voltage is 690 V maximum, with control supply accepted at 176...242 V at 50 Hz and 192...264 V at 60 Hz. The unit draws 1.63 A at 480 V and 1.72 A at 600 V.

Mounting dimensions and clearance envelope

The starter measures 45 mm wide, 155 mm deep, and 260 mm tall. It mounts vertically and requires 30 mm clearance upwards, 10 mm forwards, 10 mm downwards, and 9 mm at the side for airflow and wiring access. No backwards clearance is needed. The S0 load feeder size and S00 circuit-breaker size define the panel cutout and busbar interface. Stranded main contacts accept 1...10 mm² or 2x (2.5...6 mm²) wire.

Operating environment and approvals

The starter operates in ambient temperatures from -20 to +60 °C, stores at -50 to +80 °C, and transports at -55 to +80 °C. Pollution degree 3 means it tolerates conductive dust and condensation typical in industrial panels. Assignment type 2 coordination means the starter coordinates with a backup short-circuit protective device (typically a circuit-breaker or fuse) to ensure no damage to the starter under short-circuit conditions up to the rated breaking capacity.

Frequently asked questions

What motor power does 3RA2120-1BD23-0AP6 handle at 400 V?

It is rated for 750 W at 400 V AC-3, and also 750 W at 500 V and 1 100 W at 690 V.

What clearance is needed around this starter in a panel?

Allow 30 mm above, 10 mm in front, 10 mm below, and 9 mm to the side. No rear clearance is required. The unit mounts vertically.

MPN
3RA2120-1BD23-0AP6