Skip to main content
Siemens 3RA2120-1DA23-0AP6 — Motor Starters

Siemens 3RA2120-1DA23-0AP6 Motor Starter, S0 Size, Class 10

MPN3RA2120-1DA23-0AP6

Siemens SIRIUS 3RA2120-1DA23-0AP6 non-fused motor starter, direct starter design, S0 size, Class 10 thermal overload, 690 V AC-3, 45 mm wide, snap-on DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RA2120-1DA23-0AP6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS0
Product design / constructiondirect starter
Circuit-breaker sizeS00
Included contactor (type)3RT2023-1AP60
Included circuit-breaker (type)3RV2011-1DA10
Included link module (type)3RA2921-1AA00
3RA2120-1DA23-0AP6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V1 100 W
Operational current Ie, AC-3 at 400 V2.7 A
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)1.5 hp
Rated motor power at 575/600 V (hp)2 hp
Rated current at 480 V2.8 A
Rated current at 600 V3.16 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)10 000 000
3RA2120-1DA23-0AP6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)2.2 ... 3.2 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2
3RA2120-1DA23-0AP6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz176 ... 242 V
Auxiliary contacts, NO1
Auxiliary contacts, NC1
Auxiliary switch extensionYes
Switching contact typeelectromechanical
3RA2120-1DA23-0AP6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (16 ... 12), 2x (14 ... 8)
Mounting / fastening methodSnap-mounted to DIN rail or screw-mounted with additional push-in lug
Mounting positionvertical
Width45 mm
Height193.1 mm
Depth97.1 mm
3RA2120-1DA23-0AP6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

45 mm wide, S0 frame, Class 10 trip

The 3RA2120-1DA23-0AP6: This SIRIUS 3RA2 non-fused motor starter is a direct starter in the S0 size, 45 mm wide on the DIN rail — it takes up two standard 22.5 mm module slots in a control panel, so plan the rail accordingly.

Power ratings across the voltage range

At 400 V AC-3, the motor starter is rated for 1 100 W (1.5 hp) with a full-load current of 2.8 A; at 460/480 V it delivers 1.5 hp, and at 575/600 V it delivers 2 hp at 3.16 A — the current rating climbs with voltage as the motor draws less per horsepower. The contactor inside is a 3RT2023-1AP60, and the supplied link module is 3RA2921-1AA00 — these are the factory-matched pair, so the thermal and magnetic coordination between the contactor and overload is already set out of the box.

Frequently asked questions

What is the depth of 3RA2120-1DA23-0AP6?

97.1 mm, with 10 mm forward clearance needed for wiring and airflow. The overall height is 193.1 mm, width 45 mm.

What is the trip class of this motor starter?

This suits standard induction motors with starting times under 10 seconds.

MPN