Siemens 3RA2120-4DH27-0AV0 — Motor Starters

Siemens 3RA2120-4DH27-0AV0 SIRIUS Direct Starter

MPN3RA2120-4DH27-0AV0
Active

Siemens SIRIUS direct-on-line starter, S0 size, 11 kW at 400 V AC-3, Class 10, for 60 mm busbar systems, spring-loaded terminals.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2120-4DH27-0AV0 — Identification
ParameterValue
Product designationDirect (on-line) starter
Main circuit poles3
BrandSIRIUS
Load feeder sizeS0
Product design / constructionfor 60 mm busbars
Circuit-breaker sizeS0
Included contactor (type)3RT2027-2AV00
Included circuit-breaker (type)3RV2021-4DA20
Included link module (type)3RA2921-2AA00

Ratings & Performance

3RA2120-4DH27-0AV0 — Ratings & Performance
ParameterValue
Rated motor power at 400 V11 000 W
Operational current Ie, AC-3 at 400 V22 A
Rated voltage at AC-3, max.690 V
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)10 000 000

Protection & Tripping

3RA2120-4DH27-0AV0 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)150 000 A
Overload release setting range (current)18 ... 25 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2

Contacts & Control

3RA2120-4DH27-0AV0 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz230 ... 230 V
Control supply voltage typeAC
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Communication

3RA2120-4DH27-0AV0 — Communication
ParameterValue
AS-Interface protocol supportNo

Mechanical & Connection

3RA2120-4DH27-0AV0 — Mechanical & Connection
ParameterValue
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width45 mm
Height260 mm
Depth165 mm

Environmental

3RA2120-4DH27-0AV0 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-50 ... +80 °C
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

The 3RA2120-4DH27-0AV0: This SIRIUS direct-on-line starter is rated 11,000 W at 400 V, 50-60 Hz, with a maximum switching voltage of 690 V AC-3. That 11 kW figure at 400 V is the AC-3 motor rating — it's the current a three-phase squirrel-cage motor draws during starting and running, not a resistive load. If your motor nameplate says 11 kW at 400 V, this starter fits without derating. This protects standard motors during a stalled-rotor condition — Class 10 is the common default for general-purpose induction motors on conveyors, pumps, and fans. A higher class (20 or 30) allows longer start times for high-inertia loads, but Class 10 covers the majority of fixed-speed motor starts. The starter ships with a 3RT2027-2AV00 contactor and a 3RV2021-4DA20 circuit breaker, both spring-loaded for the main and auxiliary/control circuits. The supplied busbar adapter (8US1251-5NT11) and link module (3RA2921-2AA00) are included — no separate ordering for the busbar interface.

Snaps onto 60 mm busbars — panel layout constraints

Designed for snapping onto 60 mm busbar systems, this starter mounts vertically with a fastening method that clips directly onto standard 60 mm busbars. No DIN rail adapter is needed — the busbar adapter (8US1251-5NT11) is already supplied. Dimensions: 165 mm depth, 45 mm width, 260 mm height. Clearance requirements: 50 mm upwards, 20 mm forwards, 0 mm backwards, 10 mm downwards, 20 mm at the side. The zero backwards clearance means it can sit flush against a panel backplate — useful when sliding into a tight enclosure. The 45 mm width (roughly 1.75 inches) fits standard S0 feeder slots.

Frequently asked questions

What is the 11 kW rating at 400 V for this starter?

The 11 kW at 400 V is the AC-3 motor rating — it specifies the maximum three-phase induction motor power the starter can switch and protect under normal starting and running conditions. AC-3 covers starting currents up to 7-8× full load and breaking the motor at full load. If your motor nameplate matches 11 kW at 400 V, this part is the correct fit.