Skip to main content
Siemens 3RA2125-0GD23-0AK6 — Motor Starters

Siemens 3RA2125-0GD23-0AK6 SIRIUS Motor Starter, 690 V

MPN3RA2125-0GD23-0AK6

Siemens SIRIUS 3RA2125-0GD23-0AK6 non-fused motor starter, size S0, direct starter, 690 V rated, 180 W at 400 V, Class 10, 45 mm width, 155 mm depth, 260 mm height.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RA2125-0GD23-0AK6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS0
Product design / constructiondirect starter
Circuit-breaker sizeS00
Included contactor (type)3RT2023-1AK60
Included circuit-breaker (type)3RV2011-0GA15
Included link module (type)3RA2921-1AA00
3RA2125-0GD23-0AK6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V180 W
Operational current Ie, AC-3 at 400 V0.6 A
Rated voltage at AC-3, max.690 V
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)10 000 000
3RA2125-0GD23-0AK6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)0.45 ... 0.63 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2
3RA2125-0GD23-0AK6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz88 ... 121 V
Auxiliary contacts, NO2
Auxiliary contacts, NC2
Auxiliary switch extensionYes
Switching contact typeelectromechanical
3RA2125-0GD23-0AK6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (16 ... 12), 2x (14 ... 8)
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width45 mm
Height260 mm
Depth155 mm
3RA2125-0GD23-0AK6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

SIRIUS 3RA2 non-fused motor starter — size S0, direct start, 690 V rated

The Siemens 3RA2125-0GD23-0AK6 is a SIRIUS non-fused motor starter, size S0, configured as a direct starter. It ships with a 3RT2023-1AK60 contactor, a 3RV2011-0GA15 circuit-breaker, a 3RA2921-1AA00 link module, and an 8US1251-5NT10 busbar adapter — the BOM is self-contained for a single motor feeder. Rated voltage is 690 V, with a power rating of 180 W at 400 V and 250 W at 690 V. The overload release is thermal bimetallic, Class 10 trip class, and the short-circuit release is magnetic — this combination provides motor protection against both sustained overloads and bolted faults.

Mounting, orientation, and panel integration

Mounting is by snapping onto 60 mm busbar systems in a vertical orientation only. Clearance requirements: 30 mm upwards, 10 mm forwards, 10 mm downwards, 9 mm at the side, and 0 mm backwards. The zero backward clearance means the unit sits flush against the back panel — no extra depth needed behind the DIN rail. The wide storage range suits unheated warehouses or container shipping.

Wire sizing and auxiliary contact provision

Main contact wire range: stranded 1 to 10 mm², or 2x (2.5 to 6 mm²). AWG equivalents are 2x (16 to 12) or 2x (14 to 8). The dual-conductor capability allows paralleling smaller wires for higher ampacity without changing the terminal. The product extension for auxiliary switches is available — the feeder can accept add-on contact blocks without modifying the base unit.

Sourced through independent distribution channels. No stock-holding claim is made; each order is quoted individually.

Frequently asked questions

What is the depth of 3RA2125-0GD23-0AK6?

The depth is 155 mm. Combined with the 45 mm width and 260 mm height, the unit fits a standard 60 mm busbar system with zero backward clearance needed.

What subcomponents are supplied with 3RA2125-0GD23-0AK6?

The starter ships with a 3RT2023-1AK60 contactor, a 3RV2011-0GA15 circuit-breaker, a 3RA2921-1AA00 link module, and an 8US1251-5NT10 busbar adapter. The BOM is complete for a single motor feeder.

MPN
3RA2125-0GD23-0AK6