Siemens 3RA2125-1FA24-0AK6 — Motor Starters

Siemens 3RA2125-1FA24-0AK6 SIRIUS Motor Starter, S0 Size

MPN3RA2125-1FA24-0AK6

Siemens SIRIUS 3RA2125-1FA24-0AK6 non-fused motor starter, S0 size, CLASS 10 thermal bimetallic overload, 690 V AC-3, direct starter, snap-on DIN rail mount.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2125-1FA24-0AK6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS0
Product design / constructiondirect starter
Circuit-breaker sizeS00
Included contactor (type)3RT2024-1AK60
Included circuit-breaker (type)3RV2011-1FA15
Included link module (type)3RA2921-1AA00

Ratings & Performance

3RA2125-1FA24-0AK6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V1 500 W
Operational current Ie, AC-3 at 400 V3.6 A
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)3 hp
Rated motor power at 575/600 V (hp)3 hp
Rated current at 480 V4.8 A
Rated current at 600 V4.55 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)10 000 000

Protection & Tripping

3RA2125-1FA24-0AK6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)3.5 ... 5 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2

Contacts & Control

3RA2125-1FA24-0AK6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz88 ... 121 V
Auxiliary contacts, NO2
Auxiliary contacts, NC2
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Mechanical & Connection

3RA2125-1FA24-0AK6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (16 ... 12), 2x (14 ... 8)
Mounting / fastening methodSnap-mounted to DIN rail or screw-mounted with additional push-in lug
Mounting positionvertical
Width45 mm
Height193.1 mm
Depth97.1 mm

Environmental

3RA2125-1FA24-0AK6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

S0 direct starter for motor branch circuits

The Siemens 3RA2125-1FA24-0AK6 is a SIRIUS non-fused motor starter in the S0 frame size, combining a contactor and a thermal bimetallic overload relay in one assembly. It is configured as a direct starter, meaning it connects the motor directly across the line without reduced-voltage starting — the simplest and most common starting method for fixed-speed pumps, fans, and conveyors up to about 3 hp at 460/480 V. This is the standard trip class for general-purpose induction motors that accelerate to full speed in under 10 seconds — if the motor has a high-inertia load (centrifuge, large fan), a CLASS 20 or CLASS 30 overload might be needed, but for most pump and compressor duty this is the correct fit. Rated for AC-3 switching duty up to 690 V, the starter handles the inrush and breaking of squirrel-cage motors within its power band. At 400 V it delivers 1 500 W (about 2 hp), and at 500 V it delivers 2 200 W (about 3 hp). The thermal overload uses a bimetallic element — no electronics to fail, but ambient temperature compensation is built into the design.

Panel fit and clearance envelope

Mounting position is vertical — horizontal mounting would require a derating check against the operating temperature range of -20 to +60 °C. Dimensions are 45 mm wide, 193.1 mm high, and 97.1 mm deep — the S0 footprint is taller than the S00 size, so check the backpanel layout before committing. Clearance requirements: 30 mm upwards, 10 mm forwards, 10 mm downwards, 9 mm at the side, and 0 mm backwards. The zero backward clearance means it can sit flush against a mounting plate or busbar support without additional air gap. The supplied contactor is a 3RT2024-1AK60, and the link module is a 3RA2921-1AA00 — these are the factory-matched components inside the starter assembly. If either fails in the field, the entire starter is replaced as a unit rather than swapping individual contactor or overload parts.

Current production — sourcing posture

For volume or project pricing, submit an RFQ with the target quantity and delivery window.

MPN
3RA2125-1FA24-0AK6