Siemens 3RA2125-1HA24-0AP6 — Motor Starters

Siemens 3RA2125-1HA24-0AP6 SIRIUS Motor Starter

MPN3RA2125-1HA24-0AP6

Siemens SIRIUS 3RA2125-1HA24-0AP6 non-fused motor starter, S0 size, direct starter design, 3 kW at 400 V AC-3, Class 10 thermal bimetallic overload relay, 45 x 97.1 x 193.1 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2125-1HA24-0AP6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS0
Product design / constructiondirect starter
Circuit-breaker sizeS00
Included contactor (type)3RT2024-1AP60
Included circuit-breaker (type)3RV2011-1HA15
Included link module (type)3RA2921-1AA00

Ratings & Performance

3RA2125-1HA24-0AP6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V3 000 W
Operational current Ie, AC-3 at 400 V6.5 A
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)5 hp
Rated motor power at 575/600 V (hp)5 hp
Rated current at 480 V7.92 A
Rated current at 600 V6.33 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)10 000 000

Protection & Tripping

3RA2125-1HA24-0AP6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)5.5 ... 8 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2

Contacts & Control

3RA2125-1HA24-0AP6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz176 ... 242 V
Auxiliary contacts, NO2
Auxiliary contacts, NC2
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Mechanical & Connection

3RA2125-1HA24-0AP6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (16 ... 12), 2x (14 ... 8)
Mounting / fastening methodSnap-mounted to DIN rail or screw-mounted with additional push-in lug
Mounting positionvertical
Width45 mm
Height193.1 mm
Depth97.1 mm

Environmental

3RA2125-1HA24-0AP6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

SIRIUS 3RA2 non-fused motor starter — direct starter, S0 frame

The Siemens 3RA2125-1HA24-0AP6 is a SIRIUS non-fused motor starter in the 3RA2 family, configured as a direct starter (across-the-line) in the S0 size. It integrates a 3RT2024-1AP60 contactor and a thermal bimetallic overload relay into a single unit, saving panel space and wiring compared to a contactor-plus-relay build.

Overload protection and contactor pairing — Class 10, bimetallic

This is the correct class for most general-purpose motor starting; a Class 20 would allow longer locked-rotor time but risks winding damage on frequent starts. The supplied contactor (3RT2024-1AP60) is already wired to the overload block via the link module 3RA2921-1AA00, so the starter arrives as a single assembly. Main contact wiring accepts 1–10 mm² stranded, or 2×(2.5–6 mm²) for paralleled feeds.

Panel integration — DIN rail snap-on, S0/S00 footprint

Mounts vertically on a DIN rail via snap-on fastening, or can be screw-mounted with an additional push-in lug. The S0 size (45 mm wide, 97.1 mm deep, 193.1 mm high) fits standard 45 mm slot spacing; the circuit-breaker portion is S00 size, so the overall depth is driven by the contactor and overload block. Clearance requirements: 30 mm upward, 10 mm forward, 10 mm downward, 9 mm at the side, and 0 mm backward — the back is flush to the mounting surface. These are the minimum air gaps for heat dissipation and arc flash clearance; a panel builder should maintain them, especially when grouping multiple starters side-by-side.

Frequently asked questions

What motor power does 3RA2125-1HA24-0AP6 handle at 400 V?

At 400 V AC-3, it is rated for 3 kW (approximately 4 hp). At 460/480 V it handles 5 hp, and at 575/600 V also 5 hp. The maximum switching voltage is 690 V AC-3.

MPN
3RA2125-1HA24-0AP6