Siemens 3RA2210-0KH15-2AP0 — Motor Starters

Siemens 3RA2210-0KH15-2AP0 SIRIUS Reversing Starter, S00

MPN3RA2210-0KH15-2AP0
Active

Siemens SIRIUS 3RA2210-0KH15-2AP0 reversing starter, size S00, 1.25 A at 400 V AC-3, Class 10 trip, spring-loaded terminals, snap-on 60 mm busbar mount.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2210-0KH15-2AP0 — Identification
ParameterValue
Product designationReversing starter
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructionfor 60 mm busbars
Circuit-breaker sizeS00
Included contactor (type)3RT2015-2AP02
Included circuit-breaker (type)3RV2011-0KA20
Included link module (type)3RA2911-2AA00

Ratings & Performance

3RA2210-0KH15-2AP0 — Ratings & Performance
ParameterValue
Rated motor power at 400 V370 kW
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)0.75 hp
Rated motor power at 575/600 V (hp)0.75 hp
Rated current at 480 V1.25 A
Rated current at 600 V1.25 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V

Protection & Tripping

3RA2210-0KH15-2AP0 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)150 000 A
Overload release setting range (current)0.9 ... 1.25 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2

Contacts & Control

3RA2210-0KH15-2AP0 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz230 ... 230 V
Control supply voltage typeAC
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Communication

3RA2210-0KH15-2AP0 — Communication
ParameterValue
AS-Interface protocol supportNo

Mechanical & Connection

3RA2210-0KH15-2AP0 — Mechanical & Connection
ParameterValue
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width90 mm
Height260 mm
Depth155 mm

Environmental

3RA2210-0KH15-2AP0 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-50 ... +80 °C
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

1.25 A reversing starter, S00 frame, busbar snap-on

The 3RA2210-0KH15-2AP0: It ships as a pre-assembled unit containing the 3RT2015-2AP02 contactor and the 3RA2911-2AA00 link module, so the reversing interlock and mechanical linkage are factory-set — no field assembly of the reversing pair. Mounting is by snapping onto 60 mm busbar systems, not a DIN rail; the vertical mounting position is specified, and the enclosure clearances are 50 mm upward, 32 mm forward, 10 mm downward, and 10 mm at the side.

Trip class and termination — what they mean for the panel

The main current circuit uses spring-loaded terminals (cage-clamp style), so no screw torque verification is needed — solid or ferruled stranded wire is pushed in directly. Operating temperature range is -20 to +60 °C, with storage and transport from -50 to +80 °C — the unit can sit in an unheated warehouse or truck without damage.

MPN
3RA2210-0KH15-2AP0