Skip to main content
Siemens 3RA2210-1AD15-2AP0 — Motor Starters

Siemens 3RA2210-1AD15-2AP0 SIRIUS Reversing Starter, S00

MPN3RA2210-1AD15-2AP0
Active

Siemens SIRIUS 3RA2210-1AD15-2AP0 reversing starter, size S00, CLASS 10, 690 V, for 60 mm busbar systems, screw-type terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RA2210-1AD15-2AP0 — Identification
ParameterValue
Product designationReversing starter
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructionfor 60 mm busbars
Circuit-breaker sizeS00
Included contactor (type)3RT2015-1AP02
Included circuit-breaker (type)3RV2011-1AA10
Included link module (type)3RA1921-1DA00
3RA2210-1AD15-2AP0 — Ratings & Performance
ParameterValue
Rated motor power at 400 V550 kW
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)1 hp
Rated motor power at 575/600 V (hp)1 hp
Rated current at 480 V1.6 A
Rated current at 600 V1.6 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
3RA2210-1AD15-2AP0 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)150 000 A
Overload release setting range (current)1.1 ... 1.6 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2
3RA2210-1AD15-2AP0 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz230 ... 230 V
Control supply voltage typeAC
Auxiliary switch extensionYes
Switching contact typeelectromechanical
3RA2210-1AD15-2AP0 — Communication
ParameterValue
AS-Interface protocol supportNo
3RA2210-1AD15-2AP0 — Mechanical & Connection
ParameterValue
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width90 mm
Height204 mm
Depth155 mm
3RA2210-1AD15-2AP0 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-50 ... +80 °C
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

S00 reversing starter for 60 mm busbars

The 3RA2210-1AD15-2AP0 is a SIRIUS reversing starter, size S00, designed for snapping onto 60 mm busbar systems. It comes supplied with a 3RT2015-1AP02 contactor and a 3RA1921-1DA00 link module, so the reversing pair and overload are pre-configured as a single assembly. Rated 690 V and CLASS 10 trip, this starter handles reversing duty for motors up to 0.25 kW at 50/60 Hz. The screw-type terminals on the main current circuit take a solid connection — no push-in adapters needed.

Panel fit and mounting clearances

The unit measures 155 mm deep, 90 mm wide, and 204 mm tall. Mount it vertically; the clearance requirements are 50 mm upwards, 32 mm forwards, 10 mm downwards, and 10 mm at the side. Backwards clearance is zero — it sits flush against the busbar. Operating temperature range is -20 to +60 °C, with storage and transport limits from -50 to +80 °C. Temperature compensation is active across the full operating range.

MPN
3RA2210-1AD15-2AP0