Panel fit and mounting — S00 reversing starter
The 3RA2210-1CA15-2AK6 is a SIRIUS non-fused reversing load feeder in size S00, designed as a reversing starter with integrated overload protection. Clearance requirements: 20 mm upwards, 10 mm downwards, 9 mm at the side, and zero forwards or backwards — this allows tight rail-to-rail spacing in multi-row enclosures.
Motor duty and trip coordination
Rated for AC-3 duty up to 690 V, this reversing starter handles motor loads at 750 W at 400 V, 1 100 W at 500 V, and 1 100 W at 690 V.
Supplied components and wiring
The unit ships with a 3RT2015-1AK62 contactor and a 3RA1921-1DA00 link module pre-assembled — the contactor and overload are matched at the factory, so there is no separate selection step for the thermal element.
Environmental and compliance
Operating temperature range is -20 to +60 °C; storage and transport range is -50 to +80 °C. Pollution degree 3 (industrial environment with conductive or dry non-conductive pollution). RoHS compliance date is 10 January 2009 — the part meets EU substance restrictions.